Feasibility of Endoscopic Inspection of Pedicle Wall Integrity in a Live Surgery Model.


ABSTRACT:

Background

Perforations of the pedicle wall during cannulation can occur with experienced surgeons. Direct endoscopic visualization has not been used to inspect pedicles previously due to bone bleeding obscuring the camera visualization. The hypothesis of this study was that endoscopic visualization of pedicle wall integrity was technically feasible and would enable identification of clinically significant pedicle breaches.

Methods

A live porcine model was used. Eight lumbar pedicles were cannulated. Clinically significant breaches were created. An endoscope was introduced and was used to inspect the pedicles.

Results

All lumbar pedicles were endoscopically visible at a systolic pressure of 100 mm Hg. Clinically relevant anatomic structures and iatrogenic pathology, such as medial, lateral, and anterior breaches, were identified. There were no untoward events resulting from endoscopic inspection of the pedicle endosteal canal.

Conclusions

Endoscopic inspection of lumbar pedicles was safe and effective. The findings on endoscopic inspection corresponded with the ball-tip probe palpation techniques. Additional techniques, such as selection between 2 tracts, was possible with the endoscopic technique.

SUBMITTER: Radcliff K 

PROVIDER: S-EPMC6159636 | biostudies-literature | 2018 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Feasibility of Endoscopic Inspection of Pedicle Wall Integrity in a Live Surgery Model.

Radcliff Kristen K   Smith Harvey H   Kalantar Bobby B   Isaacs Robert R   Woods Barrett B   Vaccaro Alexander R AR   Brannon James J  

International journal of spine surgery 20180401 2


<h4>Background</h4>Perforations of the pedicle wall during cannulation can occur with experienced surgeons. Direct endoscopic visualization has not been used to inspect pedicles previously due to bone bleeding obscuring the camera visualization. The hypothesis of this study was that endoscopic visualization of pedicle wall integrity was technically feasible and would enable identification of clinically significant pedicle breaches.<h4>Methods</h4>A live porcine model was used. Eight lumbar pedic  ...[more]

Similar Datasets

| S-EPMC6904675 | biostudies-literature
| S-EPMC3233661 | biostudies-literature
| S-EPMC5987272 | biostudies-literature
| S-EPMC4677346 | biostudies-literature
| S-EPMC3312590 | biostudies-other
| S-EPMC4710572 | biostudies-literature
| S-EPMC7410376 | biostudies-literature
| S-EPMC4154971 | biostudies-other
| S-EPMC8069039 | biostudies-literature
| S-EPMC5491169 | biostudies-other