Improved glycaemic control and treatment satisfaction with a simple wearable 3-day insulin delivery device among people with Type 2 diabetes.


ABSTRACT: AIM:To evaluate the PAQ® (CeQur SA, Horw, Switzerland), a wearable 3-day insulin delivery device that provides set basal rates and bolus insulin on demand, in people with Type 2 diabetes. METHOD:Adults with Type 2 diabetes with HbA1c concentrations ?53 and ?97 mmol/mol (7.0 and 11.0%) while treated with ?2 insulin injections/day were enrolled in two single-arm studies comprising three periods: a baseline (insulin injections), a transition and a PAQ treatment period (12 weeks). Endpoints included HbA1c , seven-point self-monitored blood glucose, total daily dose of insulin and body weight. Safety was assessed according to examination, hypoglycaemic episodes and adverse device effects. RESULTS:A total of 28 adults were enrolled (age 63 ± 7 years, 86% men, BMI 32.3 ± 4.3kg/m2 , Type 2 diabetes duration 17 ± 8 years, HbA1c 70 ± 12 mmol/mol (8.6 ± 1.1%), total daily insulin dose 58.7 ± 20.7 U), of whom 24 completed the studies. When transitioned to PAQ, 75% of participants continued on the first basal rate selected. After 12 weeks of PAQ wear, significant improvements from baseline were seen [HbA1c -16 ± 9 mmol/mol (95% CI -20, -12) or -1.5 ± 0.9% (95% CI -1.8, -1.1) P<0.0001], and at all seven self-monitored blood glucose readings time points (P ?0.03). Total daily insulin dose increased by 12.1 ± 19.5 U (95% CI 3.9, 20.4; P=0.0058), the number of meal time boluses increased by 0.9 ± 1.5/day (95% CI 0.3, 1.5; P=0.0081) and body weight remained stable. Six participants had mild to moderate catheter site reactions and one mild skin irritation occurred. No participant experienced severe hypoglycaemia. CONCLUSIONS:Adults with Type 2 diabetes were safely transitioned from insulin injections to the PAQ and had significantly improved glycaemic control and treatment satisfaction with insulin therapy. (ClinicalTrials.gov identifiers: NCT02158078 & NCT02419859).

SUBMITTER: Mader JK 

PROVIDER: S-EPMC6175230 | biostudies-literature | 2018 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Improved glycaemic control and treatment satisfaction with a simple wearable 3-day insulin delivery device among people with Type 2 diabetes.

Mader J K JK   Lilly L C LC   Aberer F F   Poettler T T   Johns D D   Trautmann M M   Warner J L JL   Pieber T R TR  

Diabetic medicine : a journal of the British Diabetic Association 20180705 10


<h4>Aim</h4>To evaluate the PAQ<sup>®</sup> (CeQur SA, Horw, Switzerland), a wearable 3-day insulin delivery device that provides set basal rates and bolus insulin on demand, in people with Type 2 diabetes.<h4>Method</h4>Adults with Type 2 diabetes with HbA<sub>1c</sub> concentrations ≥53 and ≤97 mmol/mol (7.0 and 11.0%) while treated with ≥2 insulin injections/day were enrolled in two single-arm studies comprising three periods: a baseline (insulin injections), a transition and a PAQ treatment  ...[more]

Similar Datasets

| S-EPMC5638091 | biostudies-literature
| S-EPMC5342654 | biostudies-literature
| S-EPMC5379244 | biostudies-literature
| S-EPMC7775752 | biostudies-literature
| S-EPMC5942915 | biostudies-literature
| S-EPMC6099315 | biostudies-literature
| S-EPMC8914703 | biostudies-literature
| S-EPMC8586136 | biostudies-literature
| S-EPMC11019185 | biostudies-literature
| S-EPMC6629496 | biostudies-literature