Data obtained with an open-source static automated perimetry test of the full visual field in healthy adults.


ABSTRACT: The data were gathered from 98 eyes of 98 ocular healthy subjects. The subject ages ranged from 18 to 79 years with a mean (and standard deviation) of 47 (17) years. Each subject underwent two visual field tests, one of the central visual field (64 locations within 26° of fixation) and one of the peripheral visual field (64 locations with eccentricity from 26° to up to 81°). Luminance thresholds for the Goldmann size V stimulus (with a diameter of 1.72° of visual angle) were obtained with the ZEST Bayesian test procedure. Each test was conducted twice within 90 days.

SUBMITTER: Marin-Franch I 

PROVIDER: S-EPMC6187012 | biostudies-literature | 2018 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Data obtained with an open-source static automated perimetry test of the full visual field in healthy adults.

Marín-Franch Iván I   Artes Paul H PH   Chong Luke X LX   Turpin Andrew A   Wall Michael M  

Data in brief 20180929


The data were gathered from 98 eyes of 98 ocular healthy subjects. The subject ages ranged from 18 to 79 years with a mean (and standard deviation) of 47 (17) years. Each subject underwent two visual field tests, one of the central visual field (64 locations within 26° of fixation) and one of the peripheral visual field (64 locations with eccentricity from 26° to up to 81°). Luminance thresholds for the Goldmann size V stimulus (with a diameter of 1.72° of visual angle) were obtained with the ZE  ...[more]

Similar Datasets

| S-EPMC4413926 | biostudies-literature
| S-EPMC5640235 | biostudies-literature
| S-EPMC6594565 | biostudies-literature