Unknown

Dataset Information

0

Sevoflurane versus isoflurane in shoulder arthroscopy in beach chair position in patients with prior interscalene brachial plexus block: A prospective randomised equivalency-based haemodynamic evaluation trial.


ABSTRACT:

Background and aims

There is a paucity of literature on comparative effects of different inhalational anaesthetics in beach chair position (BCP) for shoulder arthroscopy. We aimed to investigate and compare the haemodynamic effects, anaesthetic and surgical outcomes between two inhalational agents.

Methods

In this randomised study, patients of age 18-60 years, were allotted to two groups (29, sevoflurane and 28, isoflurane) and received protocol-based anaesthesia. Intraoperatively, different haemodynamic and other data were recorded.

Results

All mean of averages of individual subject's vitals were comparable between the groups [P = 0.681, 0.325, 0.803, and 0.051, respectively for systolic blood pressure (SBP), diastolic blood pressure (DBP), mean blood pressure (MBP) and heart rate (HR)]. Higher mean HR was recorded for maximum readings of isoflurane (P = 0.028). Equivalency was observed for SBP, MBP, and DBP (P = 0.000, 002, and 0.027, respectively). Process capability indices indicated that sevoflurane had better values (Pp: 0.55 versus 0.41, Ppk: 0.35 versus 0.22) for SBP as with MBP (Pp: 0.62 versus 0.51, Ppk: 0.36 versus 0.33). For achieving optimal vision, higher pump pressures (PPs) were demanded by surgeon (P = 0.025) and higher differences observed between initial and highest PPs (P = 0.027), in isoflurane subjects. Multivariable analysis revealed that no continuous predictor was able to predict the quality of vision except additional pump flow factor, for both groups.

Conclusion

Both inhalational agents demonstrated equivalent haemodynamic effects. Increased arthroscopic PP requirements were observed with isoflurane anaesthesia. Sevoflurane may be superior to isoflurane during BCP arthroscopy.

SUBMITTER: Tantry TP 

PROVIDER: S-EPMC6190411 | biostudies-literature | 2018 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Sevoflurane versus isoflurane in shoulder arthroscopy in beach chair position in patients with prior interscalene brachial plexus block: A prospective randomised equivalency-based haemodynamic evaluation trial.

Tantry Thrivikrama Padur TP   Karanth Harish H   Shenoy Sunil P SP   Shetty Pramal K PK   Bhandary Sudarshan S   Adappa Karunakara K KK  

Indian journal of anaesthesia 20181001 10


<h4>Background and aims</h4>There is a paucity of literature on comparative effects of different inhalational anaesthetics in beach chair position (BCP) for shoulder arthroscopy. We aimed to investigate and compare the haemodynamic effects, anaesthetic and surgical outcomes between two inhalational agents.<h4>Methods</h4>In this randomised study, patients of age 18-60 years, were allotted to two groups (29, sevoflurane and 28, isoflurane) and received protocol-based anaesthesia. Intraoperatively  ...[more]

Similar Datasets

| S-EPMC5621929 | biostudies-literature
| S-EPMC5040097 | biostudies-literature
| S-EPMC9097375 | biostudies-literature
| S-EPMC3668105 | biostudies-literature
| S-EPMC9902626 | biostudies-literature
| S-EPMC8268244 | biostudies-literature
| S-EPMC6440401 | biostudies-literature
| S-EPMC7171737 | biostudies-literature
| S-EPMC10724485 | biostudies-literature
| S-EPMC7891753 | biostudies-literature