Validation of billing code combinations to identify cardiovascular magnetic resonance imaging scans in Ontario, Canada: a retrospective cohort study.


ABSTRACT:

Objectives

Cardiovascular magnetic resonance (CMR) imaging is the gold-standard test for the assessment of heart function. Despite its importance, many jurisdictions lack specific billing codes that can be used to identify patient receipt of CMR in administrative databases, limiting the ability to perform 'big data' CMR studies. Our objective was to identify the optimal billing code combination to identify patients who underwent CMR using administrative data in Ontario.

Design

Retrospective cohort study.

Setting

Quaternary care academic referral centre in Ontario, Canada.

Participants

We tested all billing code combinations in order to identify the optimal one to determine receipt of CMR. The reference gold standard was a list of all cardiothoracic magnetic resonance scans performed at Sunnybrook Health Sciences Centre between 1 January 2014 and 31 December 2016, verified by chart audit. We assessed the diagnostic performance (accuracy, sensitivity, specificity, positive predictive value and negative predictive value) for all code combinations.

Results

Our gold-standard cohort consisted of 2339 thoracic MRIs that were performed at Sunnybrook Health Sciences Centre from 1 January 2014 to 31 December 2016. Of these, 2139 (91.5%) were CMRs and 200 (8.5%) were chest MRIs. We identified the most accurate billing combination for the determination of patient receipt of CMR. This combination resulted in an accuracy of 95.3% (95% CI 94.4% to 96.2%), sensitivity of 97.4% (95% CI 96.6% to 98.1%), specificity of 86.4% (95% CI 83.1% to 89.6%), positive predictive value of 96.9% (95% CI 96.1% to 97.6%) and negative predictive value of 88.4% (95% CI 85.4% to 91.5%).

Conclusions

Our study is the first to verify the ability to accurately identify patient receipt of CMR using administrative data, facilitating more robust population-based CMR studies in the future.

SUBMITTER: Roifman I 

PROVIDER: S-EPMC6194470 | biostudies-literature | 2018 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Validation of billing code combinations to identify cardiovascular magnetic resonance imaging scans in Ontario, Canada: a retrospective cohort study.

Roifman Idan I   Qiu Feng F   Connelly Kim A KA   Wright Graham A GA   Farkouh Michael M   Jimenez-Juan Laura L   Wijeysundera Harindra C HC  

BMJ open 20181008 10


<h4>Objectives</h4>Cardiovascular magnetic resonance (CMR) imaging is the gold-standard test for the assessment of heart function. Despite its importance, many jurisdictions lack specific billing codes that can be used to identify patient receipt of CMR in administrative databases, limiting the ability to perform 'big data' CMR studies. Our objective was to identify the optimal billing code combination to identify patients who underwent CMR using administrative data in Ontario.<h4>Design</h4>Ret  ...[more]

Similar Datasets

| S-EPMC3861931 | biostudies-literature
| S-EPMC2871976 | biostudies-literature
| S-EPMC7457707 | biostudies-literature
| S-EPMC5898303 | biostudies-literature
| S-EPMC6208056 | biostudies-literature
| S-EPMC6234797 | biostudies-other
| S-EPMC8765105 | biostudies-literature
| S-EPMC4212584 | biostudies-literature
| S-EPMC4766895 | biostudies-literature
| S-EPMC4565176 | biostudies-literature