Project description:BACKGROUND:Perfusion assessment of the pancreas is challenging and poorly evaluated. Pancreatic affection is a prevalent feature of cystic fibrosis (CF). Little is known about pancreatic perfusion in CF. We aimed to assess pancreatic perfusion by contrast-enhanced ultrasound (CEUS) analysed in the bolus-and-burst model and software. METHODS:We performed contrast enhanced ultrasound of the pancreas in 25 CF patients and 20 healthy controls. Perfusion data was analysed using a dedicated perfusion model providing the mean capillary transit-time (MTT), blood flow (BF) and blood-volume (BV). CF patients were divided according to exocrine function. RESULTS:The pancreas insufficient CF patients had longer MTT (p ≤ 0.002), lower BF (p < 0.001) and lower BV (p < 0.05) compared to the healthy controls and sufficient CF patients. Interrater analysis showed substantial agreement for the analysis of mean transit time. CONCLUSION:The bolus-and-burst method used on pancreatic CEUS-examinations demonstrates reduced perfusion in CF patients with pancreas affection. The perfusion model and software requires further optimization and standardization to be clinical applicable for the assessment of pancreatic perfusion.
Project description:This study aimed to assess whether contrast-enhanced harmonic endoscopic ultrasonography (CH-EUS), compared to multidetector-row computed tomography (MDCT) and magnetic resonance imaging (MRI), is useful for early diagnosis of small pancreatic cancer (PC). Between March 2010 and June 2018, all three imaging modalities and surgery were performed for patients with a pancreatic solid lesion measuring ?20 mm; diagnostic ability was compared among modalities. Fifty-one of 60 patients were diagnosed with PC (PC size in 41 patients: 11-20 mm; 10 patients: ?10 mm). The sensitivity, specificity, and accuracy of CH-EUS, MDCT, and MRI for PC (11-20 mm) detection were 95%/83%/94%, 78%/83%/79%, and 73%/33%/68%, respectively. The diagnostic ability of CH-EUS was significantly superior compared with MDCT and MRI (p = 0.002 and p = 0.007, respectively). The sensitivity, specificity, and accuracy of CH-EUS, MDCT, and MRI for PC (?10 mm) detection were 70%/100%/77%, 20%/100%/38%, and 50%/100%/62%, respectively. The diagnostic ability of CH-EUS tended to be superior to that of MDCT (p = 0.025). The sensitivity of MDCT for PC (?10 mm) detection was significantly lower than that for PC (11-20 mm) detection (20% vs. 78%; p = 0.001). CH-EUS, compared to MDCT and MRI, is useful for diagnosing small PCs.
Project description:Pancreas divisum (PD) is the most common developmental anatomic variant of pancreatic duct. Endoscopic ultrasound (EUS) is often performed to evaluate idiopathic pancreatitis and has been shown to have high accuracy in diagnosis of PD. The different techniques to identify PD by linear EUS have been described differently by different authors. If EUS is done with a proper technique it can be a valuable tool in the diagnosis of PD. The anatomical and technical background of different signs has not been described so far. This article summarizes the different techniques of imaging of pancreatic duct in a suspected case of PD and gives a technical explanation of various signs. The common signs seen during evaluation of pancreatic duct in PD are stack sign of linear EUS, crossed duct sign on linear EUS, the dominant duct and ventral dorsal duct (VD) transition. Few other signs are described which include duct above duct, short ventral duct /absent ventral duct, separate opening of ducts with no communication, separate opening of ducts with filamentous communication, stacking of duct of Santorini and indirect signs like santorinecele. The principles of the sign have been explained on an anatomical basis and the techniques and the principles described in the review will be helpful in technical evaluation of PD during EUS.
Project description:The aim of this study was to review the efficacy of contrast-enhanced harmonic endoscopic ultrasonography (CH-EUS) in diagnosing gallbladder (GB)-protruded lesions. Thirty-eight patients underwent CH-EUS for the diagnosis of GB-protruded lesions. Twenty-four patients whose major axes of their largest lesions were longer than 10 mm were recruited. The ability of CH-EUS to diagnose malignant or benign lesions was reviewed. We treated lesions with brindled enhanced patterns as malignant and those with uniformly enhanced or unenhanced patterns as benign. Furthermore, three gastroenterologists who were not familiar with pancreaticobiliary EUS compared the diagnostic abilities of CH-EUS and conventional EUS using photographs. The sensitivity, specificity, and malignant accuracy of CH-EUS were 100, 94.4, and 95.8%, respectively. The number of lesions that presented with enhanced patterns was significantly different between the malignant lesions and the benign lesions (P < 0.001). In the comparison of diagnostic abilities between CH-EUS and conventional EUS by the three gastroenterologists, CH-EUS was significantly superior to conventional EUS in terms of sensitivity, specificity, and accuracy (76.1 vs. 42.9%, P = 0.029; 66.7 vs. 39.2%, P = 0.005; and 69.4 vs. 40.3%, P < 0.001; respectively). In conclusion, CH-EUS was useful for diagnosing malignant and benign GB-protruded lesions.
Project description:BackgroundCurrent practice guidelines recommend the use of ultrasound (US) as an initial surveillance tool for hepatocellular carcinoma (HCC) in patients with liver cirrhosis. Patients with liver cirrhosis, however, frequently have coarse liver parenchyma, masking the presence of tiny nodules during B-mode US. Contrast-enhanced US (CEUS) with Sonazoid has a long-lasting, stable Kupffer phase, which makes it possible to scan the entire liver to depict small lesions. In addition, defect reperfusion imaging (reinjection imaging) enables to determine whether the detected nodule is HCC or not. This prospective, multicenter, randomized, controlled trial was conducted to demonstrate the usefulness of Kupffer phase surveillance in the detection of small HCC compared to B-mode US.MethodsA total of 23 institutions joined this study. In total, 656 patients with hepatitis B- or C-related liver cirrhosis were randomized either to the B-mode US surveillance group (n = 313) or the Kupffer phase CEUS with Sonazoid surveillance group (n = 309). The primary endpoint was the maximum size of HCC at the time of the first detection. Secondary endpoints included time to HCC detection, number of tumors, and Barcelona Clinic Liver Cancer stage at the first detection, and sensitivity, specificity, and accuracy of each method in the diagnosis, and the cumulative detection rate of HCC.ResultsThe mean HCC size at the first detection was significantly smaller in the CEUS (13.0 ± 4.1 mm; n = 28) than in the B-mode US group (16.7 ± 4.1 mm; n = 26) (p = 0.011). Of the 38 patients with HCV cirrhosis diagnosed with HCC by US alone, mean tumor size at the first detection was significantly smaller in the 20 patients diagnosed by CEUS alone than in the 18 diagnosed by B-mode US alone (12.7 ± 3.1 vs. 17.6 ± 7.0 mm, p = 0.012). In contrast, among the 16 patients with HBV cirrhosis diagnosed by US alone, mean tumor size at the first detection was similar in the 8 patients diagnosed by CEUS alone and the 8 diagnosed by B-mode US (13.6 ± 6.0 vs. 14.5 ± 2.7 mm, p = 0.715).ConclusionKupffer phase CEUS surveillance with Sonazoid is extremely useful for the early detection and confirmation of HCC using a reinjection technique. Kupffer phase CEUS with Sonazoid contrast combined with the reinjection technique is, therefore, recommended as first-line screening tool for HCC in patients with liver cirrhosis, especially those with very coarse liver parenchyma.
Project description:Background/aimsRecent studies have revealed that contrast-enhanced harmonic endoscopic ultrasonography (CEH-EUS) is beneficial in the differential diagnosis of malignant neoplasms of the pancreas and gallbladder from benign masses, in terms of the evaluation of microvasculature and real-time perfusion. In this study, we aimed to prove the clinical value of CEH-EUS in the differential diagnosis of pancreatic and gallbladder masses by direct comparison with that of conventional EUS.MethodsWe reviewed the sonographic images and medical information of 471 patients who underwent conventional EUS and CEH-EUS for the diagnosis of pancreatic and gallbladder masses at a single medical center (Severance Hospital, Seoul, Korea) between March 2010 and March 2016.ResultsThe enhancement pattern of CEH-EUS of the pancreatic solid masses showed higher sensitivity and specificity in differentiating pancreatic adenocarcinoma and neuroendocrine tumors (82.0% and 87.9% for pancreatic adenocarcinoma and 81.1% and 90.9% for neuroendocrine tumors, respectively), and the area under the receiver operating characteristic curves was higher than that of conventional EUS. The enhancement texture of CEH-EUS of the gallbladder masses showed a higher sensitivity in differentiating malignant masses than that of conventional EUS; however, the difference between the areas under the receiver operating characteristic curves was not statistically significant.ConclusionsCEH-EUS can complement conventional EUS in the diagnosis of pancreatic and gallbladder masses, in terms of the limitations of the latter.
Project description:OBJECTIVE: To explore the potential of quantitative analysis of contrast-enhanced ultrasonography (CEUS) in differentiating focal nodular hyperplasia (FNH) from hepatocellular carcinoma (HCC). METHODS: 34 cases of FNH and 66 cases of HCC (all lesions <5 cm) were studied using CEUS to evaluate enhancement patterns and using analytic software Sonoliver® (Image-Arena™ v.4.0, TomTec Imaging Systems, Munich, Germany) to obtain quantitative features of CEUS in the region of interest. The quantitative features of maximum of intensity (IMAX), rise slope (RS), rise time (RT) and time to peak (TTP) were compared between the two groups and applied to further characterise both FNH and HCC with hypoenhancing patterns in the late phase on CEUS. RESULTS: The sensitivity and specificity of CEUS for diagnosis of FNH were 67.6% and 93.9%, respectively. For quantitative analysis, IMAX and RS in FNHs were significantly higher than those in HCCs (p<0.05), while RT and TTP in FNHs were significantly shorter (p<0.05). Both the 11 FNHs and 62 HCCs with hypo-enhancing patterns in the late phase were further characterised with their quantitative features, and the sensitivity and specificity of IMAX for diagnosis of FNH were 90.9% and 43.5%, RS 81.8% and 80.6%, RT 90.9% and 71.0%, and TTP 90.9% and 71.0%, respectively. CONCLUSION: The quantitative features of CEUS in FNH and HCC were significantly different, and they could further differentiate FNH from HCC following conventional CEUS. ADVANCES IN KNOWLEDGE: Our findings suggest that quantitative analysis of CEUS can improve the accuracy of differentiating FNH from HCC.
Project description:BackgroundEndoscopic ultrasonography (EUS) is proven to be a more specific and sensitive method for detecting pancreatic lesions. However, usefulness of EUS after pancreatectomy has not been reported. This study aimed to evaluate the observational capability of EUS for the remnant pancreas (RP) after pancreatectomy.Patient and methodsThis single-center, retrospective study enrolled 395 patients who underwent pancreatectomy at Onomichi General Hospital between December 2002 and March 2016, 45 patients who underwent EUS for RP were included for analysis. We evaluated the usefulness of EUS for RP using logistic regression analysis.ResultsComplete observation of the RP was done in 42 patients (93%). In the initial surgical procedure, 21 patients underwent pancreaticoduodenectomy (PD), and 24 patients underwent distal pancreatectomy (DP). PD and DP were observed in 85% (18/21) and 100% (24/24) cases, respectively. A comparison of the detection capability of EUS and contrast-enhanced computed tomography (CT) or magnetic resonance imaging (MRI) showed that EUS was significantly superior to contrast-enhanced CT or MRI (p < 0.01). Eight of the 45 patients showed recurrence lesions in the RP. The median recurrence period was 33 months. Predictive factors for recurrence in the univariate and multivariate analyses were significantly different in space occupying lesion with EUS findings (p < 0.01) and elevated CA19-9(p < 0.01).ConclusionsEUS was able to observe the RP in almost all cases. In addition, the detection capability of EUS was significantly superior to those of CT or MRI. We recommend that all patients with RP should undergo EUS, and a longer follow-up must be performed.
Project description:ObjectiveTo compare the diagnostic value of contrast-enhanced ultrasonography (CEUS) with baseline ultrasound (B-US) in ureteral neoplasms.MethodsRetrospective analysis, comprising clinical presentation, image appearances, and diagnostic results on B-ultrasound and CEUS, considering pathological result as a gold-standard, was conducted on the clinical information of 39 patients with ureteral neoplasms. CT urography was used to detect and confirm the presence of ureteral neoplasms. Both B-ultrasound and CEUS investigations of those 39 patients under study were performed by a senior radiologist.ResultsPathological outcomes established 27 ureteral malignancies and 12 ureteral benignancies. Ureteral malignancies were observed to occur in older patients than benignancies (p = 0.002). Only the morphological indicator of the ureteric wall on B-ultrasound was different in ureteral malignancies and benignancies (p = 0.030). Tumors with hyperenhancement, larger width, and hyperenhanced ureteric wall were easily diagnosed as malignant on CEUS, whereas iso-/hypoenhanced, narrower, and iso-/hypoenhanced ureteric wall indicated benign tumors. Moreover, the lesion widths, enhanced morphologies of the ureteric wall, and the ureteral wall's linear boundaries on CEUS were different between high- and low-stage ureteral urothelial carcinomas (p = 0.012, 0.002, 0.001, respectively).ConclusionThe display of microvessels in ureteral neoplasms was significantly enhanced by CEUS, thus contributing to the differential diagnosis of ureteral neoplasms while assisting the staging of ureteral urothelial carcinoma.Advances in knowledgeThe imaging features of different ureteral neoplasms on CEUS were analyzed in this study. The diagnostic performances of CEUS and B-ultrasound in ureteral urothelial carcinomas were also explored.
Project description:BackgroundQuantitative contrast-enhanced ultrasonography parameters are affected by various factors. We evaluated corrected quantitative contrast enhanced ultrasonography in differentiating benign adnexal tumors from malignant tumors.MethodsPatients with adnexal masses who underwent conventional and contrast-enhanced ultrasonography were included. Contrast-enhanced ultrasonography parameters such as base intensity, arrival time, peak intensity, time to peak intensity, ascending slope, and descending slope were measured. Corrected (time to peak intensity - arrival time) mass/(time to peak intensity - arrival time) uterus and (peak intensity - base intensity) mass/(peak intensity - base intensity) uterus were calculated. Lesions were confirmed by pathologic examination of surgical specimens.ResultsThis study included 31 patients with 35 adnexal lesions including 20 (57.10%) benign and 15 (42.90%) malignant lesions. The corrected contrast-enhanced ultrasonography quantitative parameters in lesions were statistically different between malignant and benign groups (P<0.05). The optimal cut-off value for (time to peak intensity - arrival time) mass/(time to peak intensity - arrival time) uterus, ascending slope, and (peak intensity - base intensity) mass/(peak intensity - base intensity) uterus, and descending slope for differentiating malignant adnexal masses from benign tumors were 1.05 (area under curve: 0.93, P<0.05), 1.11 (area under curve: 0.83, P<0.05), 0.82 (area under curve: 0.73, P<0.05), and -0.27 (area under curve: 0.66, P=0.16), with sensitivity and specificity of 93.33% and 85.00%, 86.67% and 75.00%, 86.67% and 60.00%, and 54.55% and 66.67%, respectively.ConclusionsCorrected contrast-enhanced ultrasonography parameters provide practical differential diagnosis value of adnexal lesions with high reliability for sonologists.