Unknown

Dataset Information

0

Ultrasensitive Quantification of Cytokine Proteins in Single Lymphocytes From Human Blood Following ex-vivo Stimulation.


ABSTRACT: In this study we demonstrate the feasibility of direct, quantitative measurement of cytokine proteins in single human CD8 lymphocytes from fresh peripheral blood of healthy donors following a brief ex vivo stimulation. Cytokine-secreting cells were identified using cell surface "catch" reagents and single cell data were obtained by sorting of individual cytokine-secreting cells into 96 well plates containing lysis buffer followed by analysis using ultrasensitive immunoassays for interferon gamma (IFN-?) and tumor necrosis factor alpha (TNF-?). CD8 cells negative for cytokine production, as determined by the cell surface catch reagents were used as negative controls. Furthermore, studies were undertaken to compare the mean fluorescence intensity (MFI) values of cytokine staining by flow cytometry with the quantification of cytokines using the current method. This study demonstrates that it is feasible to quantify cytokines from individual primary cells. A shift from qualitative to quantitative determinations of cytokine protein levels in single cells will permit more precise and reproducible studies of heterogeneity in the immune system and can be accomplished with readily available instrumentation.

SUBMITTER: Saxena A 

PROVIDER: S-EPMC6206239 | biostudies-literature | 2018

REPOSITORIES: biostudies-literature

altmetric image

Publications

Ultrasensitive Quantification of Cytokine Proteins in Single Lymphocytes From Human Blood Following <i>ex-vivo</i> Stimulation.

Saxena Ankit A   Dagur Pradeep K PK   Desai Alisha A   McCoy John Philip JP  

Frontiers in immunology 20181023


In this study we demonstrate the feasibility of direct, quantitative measurement of cytokine proteins in single human CD8 lymphocytes from fresh peripheral blood of healthy donors following a brief <i>ex vivo</i> stimulation. Cytokine-secreting cells were identified using cell surface "catch" reagents and single cell data were obtained by sorting of individual cytokine-secreting cells into 96 well plates containing lysis buffer followed by analysis using ultrasensitive immunoassays for interfero  ...[more]

Similar Datasets

| S-EPMC8050255 | biostudies-literature
| S-EPMC8187451 | biostudies-literature
| S-EPMC5627997 | biostudies-literature
2019-11-19 | GSE125214 | GEO
| S-EPMC3603277 | biostudies-literature
| S-EPMC10707883 | biostudies-literature
| S-EPMC8611197 | biostudies-literature
| S-EPMC7863610 | biostudies-literature
| S-EPMC3847989 | biostudies-literature
2019-11-19 | GSE125212 | GEO