Unknown

Dataset Information

0

Differential Assessment of Factor Xa Activity and Global Blood Coagulability Utilizing Novel Dielectric Coagulometry.


ABSTRACT: An easy-to-use assessment for activated factor X (FXa) is lacking despite its pivotal role in the coagulation. Dielectric blood coagulometry (DBCM) was recently invented as a novel assessment tool for determining the whole blood coagulability by measuring the temporal change in the permittivity of blood. We previously reported that it could evaluate the global blood coagulability. This study aimed to apply the DBCM for assessing FXa activity and its inhibition by anticoagulants. We performed the DBCM analysis along with measurement of the FXa activity by a fluorometric assay in samples from healthy subjects, and identified a new index named maximum acceleration time (MAT) that had a correlation to the FXa activity. Next the DBCM analysis was performed using blood samples mixed with anticoagulants (unfractionated heparin, dalteparin, and edoxaban). Blood samples with three anticoagulants had different profiles of the temporal change in the permittivity, reflecting their different selectivity for FXa. We compared the MAT with the anti-FXa activity assay, and found that the prolongation of MAT was similarly correlated with the anti-FXa activity regardless of the type of anticoagulants. In conclusion, the DBCM has the possibility for evaluating the innate FXa activity and effect of anticoagulants focusing on their FXa inhibition.

SUBMITTER: Hamada S 

PROVIDER: S-EPMC6208345 | biostudies-literature | 2018 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Differential Assessment of Factor Xa Activity and Global Blood Coagulability Utilizing Novel Dielectric Coagulometry.

Hamada Satomi S   Hasegawa Yuki Y   Oono Ai A   Suzuki Anna A   Takahashi Naomi N   Nishimura Takuro T   Koyama Takatoshi T   Hagihara Michio M   Tohda Shuji S   Furukawa Tetsushi T   Hirao Kenzo K   Sasano Tetsuo T  

Scientific reports 20181031 1


An easy-to-use assessment for activated factor X (FXa) is lacking despite its pivotal role in the coagulation. Dielectric blood coagulometry (DBCM) was recently invented as a novel assessment tool for determining the whole blood coagulability by measuring the temporal change in the permittivity of blood. We previously reported that it could evaluate the global blood coagulability. This study aimed to apply the DBCM for assessing FXa activity and its inhibition by anticoagulants. We performed the  ...[more]

Similar Datasets

| S-EPMC5597622 | biostudies-literature
| S-EPMC8516376 | biostudies-literature
| S-EPMC6273828 | biostudies-literature
| S-EPMC3824214 | biostudies-literature
| S-EPMC22577 | biostudies-literature
| S-EPMC7149769 | biostudies-literature
| S-EPMC4451689 | biostudies-literature
| S-EPMC2823678 | biostudies-literature
| S-EPMC5541968 | biostudies-other
| S-EPMC5554137 | biostudies-other