Developmental validation of GlobalFiler™ PCR amplification kit: a 6-dye multiplex assay designed for amplification of casework samples.


ABSTRACT: The GlobalFiler™ PCR Amplification Kit is a single multiplex assay that amplifies a set of 24 markers, which encompass the European Standard Set and CODIS (Combined DNA Index System) recommended composite set of loci. In addition to more loci and a 6-dye chemistry format, the Master Mix has been formulated to allow higher sample loading volume for trace DNA samples. The GlobalFiler™ Kit has been optimized to deliver high performance on casework samples, while also delivering fast thermal cycling, with an amplification time of approximately 80 min. Here, we report the results of the developmental validation study which followed the SWGDAM (Scientific Working Group on DNA Analysis Methods) guidelines and includes data for PCR-based studies, sensitivity, species specificity, stability, precision, reproducibility and repeatability, concordance, stutter, DNA mixtures, and performance on mock casework samples. The results validate the multiplex design as well as demonstrate the kit's robustness, reliability, and suitability as an assay for human identification with casework DNA samples.

SUBMITTER: Ludeman MJ 

PROVIDER: S-EPMC6208722 | biostudies-literature | 2018 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Developmental validation of GlobalFiler™ PCR amplification kit: a 6-dye multiplex assay designed for amplification of casework samples.

Ludeman Matthew J MJ   Zhong Chang C   Mulero Julio J JJ   Lagacé Robert E RE   Hennessy Lori K LK   Short Marc L ML   Wang Dennis Y DY  

International journal of legal medicine 20180309 6


The GlobalFiler™ PCR Amplification Kit is a single multiplex assay that amplifies a set of 24 markers, which encompass the European Standard Set and CODIS (Combined DNA Index System) recommended composite set of loci. In addition to more loci and a 6-dye chemistry format, the Master Mix has been formulated to allow higher sample loading volume for trace DNA samples. The GlobalFiler™ Kit has been optimized to deliver high performance on casework samples, while also delivering fast thermal cycling  ...[more]

Similar Datasets

| S-EPMC9546378 | biostudies-literature
| S-EPMC2675535 | biostudies-literature
| S-EPMC8164790 | biostudies-literature
| S-EPMC9246015 | biostudies-literature
| S-EPMC7760956 | biostudies-literature
| S-EPMC14569 | biostudies-literature
| S-EPMC3494155 | biostudies-literature
| S-EPMC7786945 | biostudies-literature
| S-EPMC3422993 | biostudies-literature
| S-EPMC8451954 | biostudies-literature