Decoupling Between Diastolic Pulmonary Arterial Pressure and Pulmonary Arterial Wedge Pressure at Incremental Left Ventricular Assist Device (LVAD) Speeds Is Associated With Worse Prognosis After LVAD Implantation.


ABSTRACT: BACKGROUND:Decoupling between diastolic pulmonary arterial pressure (dPAP) and pulmonary arterial wedge pressure (PAWP) is an index of pulmonary vasculature remodeling and provides prognostic information. Furthermore, decoupling may change during incremental left ventricular assist device (LVAD) speed changes. METHODS AND RESULTS:In this prospective study, patients underwent an echocardiographic and hemodynamic ramp test after LVAD implantation and were followed for 1 year. The change in decoupling (dPAP?-?PAWP) between the lowest and highest LVAD speeds during the ramp test was calculated. Survival and heart failure admission rates were assessed by means of Kaplan-Meier analysis. Eighty-seven patients were enrolled in the study: 54 had a Heartmate II LVAD (60.8 ± 9.3 years of age and 34 male) and 33 had an HVAD LVAD (58.6 ± 13.2 years of age and 20 male). Patients who experienced greater changes in decoupling (?decoupling >3 mm Hg) had a persistently elevated dPAP at incremental LVAD speed and had worse 1-year heart failure readmission-free survival compared with the group without significant changes in the degree of decoupling (41% vs 75%; P?=?.001). CONCLUSIONS:An increase in decoupling between dPAP and PAWP at incremental LVAD speed changes was associated with worse prognosis in LVAD patients.

SUBMITTER: Imamura T 

PROVIDER: S-EPMC6221832 | biostudies-literature | 2018 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Decoupling Between Diastolic Pulmonary Arterial Pressure and Pulmonary Arterial Wedge Pressure at Incremental Left Ventricular Assist Device (LVAD) Speeds Is Associated With Worse Prognosis After LVAD Implantation.

Imamura Teruhiko T   Kim Gene G   Raikhelkar Jayant J   Sarswat Nitasha N   Kalantari Sara S   Smith Bryan B   Rodgers Daniel D   Chung Ben B   Nguyen Ann A   Ota Takeyoshi T   Song Tae T   Juricek Colleen C   Jeevanandam Valluvan V   Burkhoff Daniel D   Sayer Gabriel G   Uriel Nir N  

Journal of cardiac failure 20180810 9


<h4>Background</h4>Decoupling between diastolic pulmonary arterial pressure (dPAP) and pulmonary arterial wedge pressure (PAWP) is an index of pulmonary vasculature remodeling and provides prognostic information. Furthermore, decoupling may change during incremental left ventricular assist device (LVAD) speed changes.<h4>Methods and results</h4>In this prospective study, patients underwent an echocardiographic and hemodynamic ramp test after LVAD implantation and were followed for 1 year. The ch  ...[more]

Similar Datasets

| S-EPMC5745161 | biostudies-literature
| S-EPMC6224703 | biostudies-literature
| S-EPMC7754752 | biostudies-literature
| S-EPMC3955214 | biostudies-literature
| S-EPMC8712584 | biostudies-literature
| S-EPMC6643191 | biostudies-literature
| S-EPMC3264431 | biostudies-literature
| S-EPMC8618201 | biostudies-literature
| S-EPMC3603556 | biostudies-literature
| S-EPMC8453715 | biostudies-literature