Unknown

Dataset Information

0

Retinal-image quality and contrast sensitivity function in eyes with epiretinal membrane: a cross-sectional observational clinical study.


ABSTRACT:

Background

To investigate the effect of idiopathic epiretinal membrane (ERM) on the retinal-image quality and psychophysical contrast sensitivity function (CSF).

Methods

Forty-four subjects with diagnosis of idiopathic unilateral ERM were enrolled in this cross-sectional observational clinical study. The fellow unaffected eyes were set as the control group. For retinal-image quality assessment, an Optical Quality Analysis System (OQAS) based on double-pass technique was used to evaluate objective scatter index (OSI) and Strehl ratio. For visual performance, the CSF under photopic condition was measured.

Results

For retinal-image quality, the result of double-pass device revealed a significant lower Strehl ratio and larger OSI in the ERM eyes compared to the fellow eyes (all P?ConclusionEyes affected with ERM showed poorer retinal-image quality and visual performance than the normal eyes. Retinal-image quality measured by OQAS based on double-pass technique could be useful for assessing the retinal-image quality for ERM-affected eyes, in which retinal scattering was significantly increased.

SUBMITTER: Liu L 

PROVIDER: S-EPMC6223062 | biostudies-literature | 2018 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Retinal-image quality and contrast sensitivity function in eyes with epiretinal membrane: a cross-sectional observational clinical study.

Liu Limei L   Wang Yi Y   Liu Ju J   Liu Wu W  

BMC ophthalmology 20181107 1


<h4>Background</h4>To investigate the effect of idiopathic epiretinal membrane (ERM) on the retinal-image quality and psychophysical contrast sensitivity function (CSF).<h4>Methods</h4>Forty-four subjects with diagnosis of idiopathic unilateral ERM were enrolled in this cross-sectional observational clinical study. The fellow unaffected eyes were set as the control group. For retinal-image quality assessment, an Optical Quality Analysis System (OQAS) based on double-pass technique was used to ev  ...[more]

Similar Datasets

| S-EPMC8927570 | biostudies-literature
| S-EPMC10156972 | biostudies-literature
| S-EPMC5838718 | biostudies-literature
| S-EPMC6445520 | biostudies-literature
| S-EPMC5848276 | biostudies-literature
| S-EPMC9644160 | biostudies-literature
| S-EPMC7790294 | biostudies-literature
| S-EPMC7886026 | biostudies-literature
| S-EPMC4747534 | biostudies-literature
| S-EPMC5436669 | biostudies-literature