Unknown

Dataset Information

0

Comparative Performances of Dipyridamole and Regadenoson to Detect Myocardial Ischemia using Cardiac Cadmium-Zinc-Telluride Single-Photon Emission Computerized Tomography.


ABSTRACT: Objective:We evaluated the relative performances of dipyridamole (Dip) and regadenoson (Reg) in a cohort of patients referred for coronary artery disease diagnosis or follow-up using myocardial perfusion imaging. Materials and Methods:We retrospectively included 515 consecutive patients referred for 99mTc-sestamibi myocardial perfusion single-photon emission computerized tomography (SPECT) on a cadmium-zinc-telluride (CZT) camera after pharmacologic stress. About three quarters (n = 391, 76%) received Dip. Reg was administrated to patients with chronical respiratory disease or with body mass index (BMI) over 38 kg/m2 (n = 124, 24%). Patients with an abnormal stress scan (92%) underwent a rest imaging on the same day. Qualitative interpretation of perfusion images was achieved using QPS software, and the ischemic area was assessed using the 17-segment model. In patients undergoing a stress-rest protocol, perfusion polar plots were postprocessed using automated in-house software to quantify the extension, intensity, and location of the reversible perfusion defect. Statistical comparison between groups was performed using univariate and multivariate analysis. Results:Qualitative analysis concluded to myocardial ischemia in 70% of the patients (69% in the Dip group, 76% in the Reg group, P = ns). In those patients, the number of involved segments (Dip 2.5 ± 1.6, Reg 2.7 ± 1.6, P = ns) and the proportion of patients with an ischemic area larger than two segments (Dip 30%, Reg 37%, P = ns) were comparable. Automated quantification of the reversible perfusion defect demonstrated similar defect extension, intensity, and severity in the two groups. Defect location was identical at the myocardial segment and vascular territory scales. Conclusions:Reg and Dip showed equal performances for ischemic burden characterization using myocardial CZT SPECT.

SUBMITTER: Bouallcgue FB 

PROVIDER: S-EPMC6251245 | biostudies-literature | 2018

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparative Performances of Dipyridamole and Regadenoson to Detect Myocardial Ischemia using Cardiac Cadmium-Zinc-Telluride Single-Photon Emission Computerized Tomography.

Bouallçgue Fayçal Ben FB   Nganoa Catherine C   Vigne Jonathan J   Agostini Denis D   Manrique Alain A  

Journal of clinical imaging science 20181115


<h4>Objective</h4>We evaluated the relative performances of dipyridamole (Dip) and regadenoson (Reg) in a cohort of patients referred for coronary artery disease diagnosis or follow-up using myocardial perfusion imaging.<h4>Materials and methods</h4>We retrospectively included 515 consecutive patients referred for <sup>99m</sup>Tc-sestamibi myocardial perfusion single-photon emission computerized tomography (SPECT) on a cadmium-zinc-telluride (CZT) camera after pharmacologic stress. About three  ...[more]

Similar Datasets

| S-EPMC10547640 | biostudies-literature
| S-EPMC10072870 | biostudies-literature
| S-EPMC3808444 | biostudies-other
| S-EPMC6536350 | biostudies-literature
| S-EPMC5607867 | biostudies-literature
| S-EPMC5013605 | biostudies-literature
| S-EPMC10293939 | biostudies-literature
| S-EPMC4595592 | biostudies-literature
| S-EPMC5003732 | biostudies-literature
| S-EPMC5552647 | biostudies-literature