Performance of the 10-2 and 24-2 Visual Field Tests for Detecting Central Visual Field Abnormalities in Glaucoma.


ABSTRACT: PURPOSE:To compare the performance of the pattern standard deviation (PSD) values derived from the central 12 locations of the 24-2 visual field test (C24-2) to the entire 10-2 test for detecting central visual field abnormalities in eyes with, suspected of having, or at risk of having glaucoma. DESIGN:Cross-sectional case-control study. METHODS:Eyes with, suspected of having, or at risk of having glaucoma, based on masked grading of optic disc stereophotographs and/or ocular hypertension (intraocular pressure ? 22 mm Hg) were included as cases (n = 523). Eyes from healthy participants were included as controls (n = 107) to allow the 2 tests to be compared at matched specificities. The sensitivity to detect cases at 95% specificity using PSD values derived from the entire 10-2 test and C24-2 were compared. RESULTS:The sensitivity of the 10-2 and C24-2 PSD values was not significantly different between the 10-2 and C24-2 at matched specificities (35.9% and 35.4% respectively; P = .900). There was also a substantial agreement between the cases detected by both methods (kappa = 0.80 ± 0.04), and a very strong association between the PSD values from the 2 methods (R2 = 0.91). CONCLUSIONS:10-2 and 24-2 tests identified a similar number of eyes with, suspected of having, or at risk of having glaucoma as having central visual field abnormalities using PSD values. These findings do not mean that 10-2 tests are not useful, but highlight the need for further studies to determine the potential advantages of 10-2 tests through equivalent comparisons against 24-2 tests to ensure appropriate recommendations are made about its incorporation into the glaucoma standard of care.

SUBMITTER: Wu Z 

PROVIDER: S-EPMC6258276 | biostudies-literature | 2018 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Performance of the 10-2 and 24-2 Visual Field Tests for Detecting Central Visual Field Abnormalities in Glaucoma.

Wu Zhichao Z   Medeiros Felipe A FA   Weinreb Robert N RN   Zangwill Linda M LM  

American journal of ophthalmology 20180810


<h4>Purpose</h4>To compare the performance of the pattern standard deviation (PSD) values derived from the central 12 locations of the 24-2 visual field test (C24-2) to the entire 10-2 test for detecting central visual field abnormalities in eyes with, suspected of having, or at risk of having glaucoma.<h4>Design</h4>Cross-sectional case-control study.<h4>Methods</h4>Eyes with, suspected of having, or at risk of having glaucoma, based on masked grading of optic disc stereophotographs and/or ocul  ...[more]

Similar Datasets

| S-EPMC8379296 | biostudies-literature
| S-EPMC6860370 | biostudies-literature
| S-EPMC5610609 | biostudies-literature
| S-EPMC8606810 | biostudies-literature
| S-EPMC7246163 | biostudies-literature
| S-EPMC6802178 | biostudies-literature
| S-EPMC5837938 | biostudies-literature
| S-EPMC5376509 | biostudies-literature
| S-EPMC9640563 | biostudies-literature
| S-EPMC6990977 | biostudies-literature