Impella CP-assisted balloon aortic valvuloplasty.


ABSTRACT: Percutaneous ventricular assist device (PVAD) use in balloon aortic valvuloplasty (BAV) has been performed sporadically. The PVAD used was TandemHeart. A few cases were reported using Impella 2.5 device. We report the first case of Impella CP-assisted BAV. The use of PVAD has been contraindicated in severe aortic stenosis (AS). However, the various benefits of PVAD, including circulatory support and minimizing interruption of blood flow during balloon inflation, made its use attractive in high-risk BAV. We recommend that severe AS no more stays as a contraindication to the use of PVADs. .