Unknown

Dataset Information

0

Quantification of protein mobility and associated reshuffling of cytoplasm during chemical fixation.


ABSTRACT: To understand cellular functionalities, it is essential to unravel spatio-temporal patterns of molecular distributions and interactions within living cells. The technological progress in fluorescence microscopy now allows in principle to measure these patterns with sufficient spatial resolution. However, high resolution imaging comes with long acquisition times and high phototoxicity. Therefore, physiological live cell imaging is often unfeasible and chemical fixation is employed. Yet, fixation methods have not been rigorously investigated, in terms of pattern preservation, at the resolution at which cells can now be imaged. A key parameter for this is the time required until fixation is complete. During this time, cells are under unphysiological conditions and patterns decay. We demonstrate here that formaldehyde fixation takes more than one hour for cytosolic proteins in cultured cells. Other small aldehydes, glyoxal and acrolein, did not perform better. Associated with this, we found a distinct displacement of proteins and lipids, including their loss from cells. Fixations using glutaraldehyde were faster than four minutes and retained most cytoplasmic proteins. Surprisingly, autofluorescence produced by glutaraldehyde was almost completely absent with supplementary addition of formaldehyde without compromising fixation speed. These findings indicate, which cellular processes can actually be reliably imaged after a certain chemical fixation.

SUBMITTER: Huebinger J 

PROVIDER: S-EPMC6288139 | biostudies-literature | 2018 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Quantification of protein mobility and associated reshuffling of cytoplasm during chemical fixation.

Huebinger Jan J   Spindler Jessica J   Holl Kristin J KJ   Koos Björn B  

Scientific reports 20181210 1


To understand cellular functionalities, it is essential to unravel spatio-temporal patterns of molecular distributions and interactions within living cells. The technological progress in fluorescence microscopy now allows in principle to measure these patterns with sufficient spatial resolution. However, high resolution imaging comes with long acquisition times and high phototoxicity. Therefore, physiological live cell imaging is often unfeasible and chemical fixation is employed. Yet, fixation  ...[more]

Similar Datasets

| S-EPMC3476290 | biostudies-literature
| S-EPMC9746315 | biostudies-literature
| S-EPMC3086679 | biostudies-literature
| S-EPMC5675743 | biostudies-literature
2008-11-19 | E-GEOD-12204 | biostudies-arrayexpress
| S-EPMC139231 | biostudies-literature
| S-EPMC4591358 | biostudies-literature
| S-EPMC2865363 | biostudies-literature
2008-11-20 | GSE12204 | GEO
| S-EPMC5726765 | biostudies-literature