Unknown

Dataset Information

0

Reliability of Wearable-Sensor-Derived Measures of Physical Activity in Wheelchair-Dependent Spinal Cord Injured Patients.


ABSTRACT: Physical activity (PA) has been shown to have a positive influence on functional recovery in patients after a spinal cord injury (SCI). Hence, it can act as a confounder in clinical intervention studies. Wearable sensors are used to quantify PA in various neurological conditions. However, there is a lack of knowledge about the inter-day reliability of PA measures. The objective of this study was to investigate the single-day reliability of various PA measures in patients with a SCI and to propose recommendations on how many days of PA measurements are required to obtain reliable results. For this, PA of 63 wheelchair-dependent patients with a SCI were measured using wearable sensors. Patients of all age ranges (49.3 ± 16.6 years) and levels of injury (from C1 to L2, ASIA A-D) were included for this study and assessed at three to four different time periods during inpatient rehabilitation (2 weeks, 1 month, 3 months, and if applicable 6 months after injury) and after in-patient rehabilitation in their home-environment (at least 6 months after injury). The metrics of interest were total activity counts, PA intensity levels, metrics of wheeling quantity and metrics of movement quality. Activity counts showed consistently high single-day reliabilities, while measures of PA intensity levels considerably varied depending on the rehabilitation progress. Single-day reliabilities of metrics of movement quantity decreased with rehabilitation progress, while metrics of movement quality increased. To achieve a mean reliability of 0.8, we found that three continuous recording days are required for out-patients, and 2 days for in-patients. Furthermore, the results show similar weekday and weekend wheeling activity for in- and out-patients. To our knowledge, this is the first study to investigate the reliability of an extended set of sensor-based measures of PA in both acute and chronic wheelchair-dependent SCI patients. The results provide recommendations for sensor-based assessments of PA in clinical SCI studies.

SUBMITTER: Schneider S 

PROVIDER: S-EPMC6295582 | biostudies-literature | 2018

REPOSITORIES: biostudies-literature

altmetric image

Publications

Reliability of Wearable-Sensor-Derived Measures of Physical Activity in Wheelchair-Dependent Spinal Cord Injured Patients.

Schneider Sophie S   Popp Werner L WL   Brogioli Michael M   Albisser Urs U   Demkó László L   Debecker Isabelle I   Velstra Inge-Marie IM   Gassert Roger R   Curt Armin A  

Frontiers in neurology 20181210


Physical activity (PA) has been shown to have a positive influence on functional recovery in patients after a spinal cord injury (SCI). Hence, it can act as a confounder in clinical intervention studies. Wearable sensors are used to quantify PA in various neurological conditions. However, there is a lack of knowledge about the inter-day reliability of PA measures. The objective of this study was to investigate the single-day reliability of various PA measures in patients with a SCI and to propos  ...[more]

Similar Datasets

| S-EPMC6420014 | biostudies-literature
| S-EPMC7569950 | biostudies-literature
| S-EPMC6293371 | biostudies-literature
| S-EPMC3689933 | biostudies-literature
| S-EPMC10008620 | biostudies-literature
| S-EPMC10427619 | biostudies-literature
| S-EPMC7189380 | biostudies-literature
| S-EPMC10060131 | biostudies-literature
| S-EPMC8197742 | biostudies-literature
| S-EPMC5749801 | biostudies-literature