Correlation of pacing site in right ventricle with paced QRS complex duration.


ABSTRACT: BACKGROUND:Pacing from RV mid septum and outflow tract septum has been proposed as a more physiological site of pacing and narrower paced QRS complex duration. The paced QRS morphology and duration in different RV pacing sites is under continued discussion. Hence, this study was designed to address the correlation of pacing sites in right ventricle with paced QRS complex duration. METHODS:Two hundred fifty-two consecutive patients who underwent pacemaker implantation were enrolled. Baseline clinical characteristics were recorded for each patient. All patient underwent fluoroscopy, electrocardiogram and echocardiography post pacemaker implantation. Paced QRS duration was calculated from the leads with maximum QRS duration. RESULTS:Mean paced QRS (pQRS) duration was significantly higher in apical septum group with a mean of 148.9?±?14.8?m?s compared to mid septum (139.6?±?19.9?m?s; p-value 0.003) and RVOT septum (139.6?±?14.8?m?s; p-value 0.002) groups, respectively. There was no significant difference between mid-septal and RVOT septal pQRS duration. On multivariate analysis, female gender, baseline QRS duration and RVOT septal pacing were the only predictors for narrow pQRS duration (<150?msec). CONCLUSION:RV mid-septal and RVOT septal pacing were associated with significantly lower pQRS duration as compared with apical pacing. Based on multivariate analysis RVOT septal pacing appears to be preferred and more physiological pacing site.

SUBMITTER: Gupta A 

PROVIDER: S-EPMC6302778 | biostudies-literature | 2018 Nov - Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Correlation of pacing site in right ventricle with paced QRS complex duration.

Gupta Anunay A   Parakh Neeraj N   Bansal Raghav R   Verma Sunil K SK   Roy Ambuj A   Sharma Gautam G   Yadav Rakesh R   Naik Nitish N   Juenja Rajnish R   Bahl Vinay K VK  

Indian pacing and electrophysiology journal 20180817 6


<h4>Background</h4>Pacing from RV mid septum and outflow tract septum has been proposed as a more physiological site of pacing and narrower paced QRS complex duration. The paced QRS morphology and duration in different RV pacing sites is under continued discussion. Hence, this study was designed to address the correlation of pacing sites in right ventricle with paced QRS complex duration.<h4>Methods</h4>Two hundred fifty-two consecutive patients who underwent pacemaker implantation were enrolled  ...[more]

Similar Datasets

| S-EPMC7501936 | biostudies-literature
| S-EPMC8190182 | biostudies-literature
| S-EPMC10721664 | biostudies-literature
| S-EPMC5143452 | biostudies-literature
| S-EPMC6693931 | biostudies-literature
| S-EPMC6441681 | biostudies-literature
| S-EPMC7336018 | biostudies-literature
| S-EPMC4070771 | biostudies-literature
| S-EPMC6027639 | biostudies-literature
| S-EPMC8084404 | biostudies-literature