Validity and Reliability of the GymAware Linear Position Transducer for Squat Jump and Counter-Movement Jump Height.


ABSTRACT: The purpose of this study was to assess the concurrent validity and test-retest reliability of a linear position transducer (LPT) for the squat jump (SJ) and counter-movement jump (CMJ) height. Twenty-eight subjects (25.18 ± 7.1 years) performed three SJs followed by three CMJs using a force plate concurrently with the LPT to test validity. Subjects returned on a separate day, at least 48 h apart, to measure test-retest reliability. A t-test showed a significant difference between the two devices for both SJ (p < 0.001) and CMJ (p < 0.001) while Bland?Altman analysis for validity revealed that the LPT overestimated jump height for both SJ (mean difference (MD) = 8.01 ± 2.93 cm) and CMJ (MD = 8.68 ± 2.99 cm). With regards to reliability of the LPT, mean intraclass correlation (ICC) for both SJ (ICC = 0.84) and CMJ (ICC = 0.95) were high, and Bland?Altman analysis showed mean differences lower than minimal detectable change (MDC) between the days for both SJ (MD = 1.89 ± 4.16 cm vs. MDC = 2.72 cm) and CMJ (MD = 0.47 ± 3.23 cm vs. MDC = 2.11 cm). Additionally, there was a low coefficient of variation (CV) between days for both SJ (CV = 3.25%) and CMJ (CV = 0.74%). Therefore, while the LPT overestimates jump height, it is a reliable tool for tracking changes in jump height to measure performance improvement and monitor fatigue.

SUBMITTER: Wadhi T 

PROVIDER: S-EPMC6316460 | biostudies-literature | 2018 Dec

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC6193468 | biostudies-literature
| S-EPMC7216608 | biostudies-literature
| S-EPMC5933316 | biostudies-literature
| S-EPMC2998461 | biostudies-literature
| S-EPMC5548151 | biostudies-other
| S-EPMC7183057 | biostudies-literature
| S-EPMC7581857 | biostudies-literature
| S-EPMC4950838 | biostudies-literature