Unknown

Dataset Information

0

Potential usefulness of 68Ga-citrate PET/CT in detecting infected lower limb prostheses.


ABSTRACT: BACKGROUND:Prosthetic joint infections may lead to failures of total joint arthroplasty. Radionuclide imaging can play a diagnostic role in identifying such infections, which require two-stage exchange arthroplasty (instead of simple revision surgery performed in non-infected cases). Although 18F-FDG PET/CT has emerged as a novel diagnostic tool in this setting, the clinical usefulness of 68Ga-citrate PET/CT has not been previously investigated. This single-center prospective study was designed to address this issue. METHODS:Between January 2016 and October 2017, we examined 34 patients with clinically proven or suspected prosthetic hip/knee joint infections scheduled to undergo surgery. All patients underwent 68Ga-citrate PET/CT scans and sequential 18F-FDG PET/CT imaging for comparative purposes. Intraoperative findings and the results of microbiological analyses of surgical specimens served as gold standard. The diagnostic results were examined according to (1) image interpretation based on radiotracer uptake patterns and (2) quantitative analysis using volumes of interest (VOIs) to calculate standard uptake values (SUVs) and metabolic volumes (MVs). RESULTS:A total of 26 (76%) patients were diagnosed as having infections. Based on radiotracer uptake pattern criteria, the sensitivity, specificity, and accuracy of 68Ga-citrate PET/CT and 18F-FDG PET/CT were 92%, 88%, and 91% and 100%, 38%, and 85%, respectively. MV was significantly higher in the infected group when 68Ga-citrate PET/CT was used (422.45 vs. 303.65 cm3, p?=?0.027), whereas no significant differences were observed on 18F-FDG PET/CT. According to receiver operating characteristic (ROC) curve analysis, a cut-off value of 370.86 for MV resulted in a sensitivity of 61.5% and a specificity of 87.5% (area under curve: 0.75, 95% confidence interval: 0.57-0.88, p?=?0.035). CONCLUSIONS:Subject to future confirmation, our data provide preliminary evidence that 68Ga-citrate PET/CT may have a complimentary role to 18F-FDG PET/CT in detecting prosthetic joint infections, being characterized by a higher specificity and the possibility to discriminate between an infectious condition and sterile inflammation. TRIAL REGISTRATION:This prospective study was registered at clinicaltrials.gov (registration number: NCT02855190 ).

SUBMITTER: Tseng JR 

PROVIDER: S-EPMC6318156 | biostudies-literature | 2019 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Potential usefulness of <sup>68</sup>Ga-citrate PET/CT in detecting infected lower limb prostheses.

Tseng Jing-Ren JR   Chang Yu-Han YH   Yang Lan-Yan LY   Wu Chen-Te CT   Chen Szu-Yuan SY   Wan Chih-Hsing CH   Hsiao Ing-Tsung IT   Yen Tzu-Chen TC  

EJNMMI research 20190103 1


<h4>Background</h4>Prosthetic joint infections may lead to failures of total joint arthroplasty. Radionuclide imaging can play a diagnostic role in identifying such infections, which require two-stage exchange arthroplasty (instead of simple revision surgery performed in non-infected cases). Although <sup>18</sup>F-FDG PET/CT has emerged as a novel diagnostic tool in this setting, the clinical usefulness of <sup>68</sup>Ga-citrate PET/CT has not been previously investigated. This single-center p  ...[more]

Similar Datasets

| S-EPMC6502703 | biostudies-literature
| S-EPMC5227553 | biostudies-literature
| S-EPMC5664237 | biostudies-literature
| S-EPMC6238742 | biostudies-other
| S-EPMC6581743 | biostudies-literature
| S-EPMC9538925 | biostudies-literature
| S-EPMC5745571 | biostudies-literature
| S-EPMC5300187 | biostudies-literature
| S-EPMC6263676 | biostudies-literature
| S-EPMC6711521 | biostudies-literature