Unknown

Dataset Information

0

A Decision Analysis Model of 1-Year Effectiveness of Intended Postplacental Compared With Intended Delayed Postpartum Intrauterine Device Insertion.


ABSTRACT: OBJECTIVE:To compare, using decision analysis methodology, the 1-year probability of pregnancy after intended postplacental intrauterine device (IUD) insertion with intended delayed insertion at an outpatient postpartum visit (delayed postpartum placement). METHODS:We developed an evidence-based decision model with the primary outcome of 1-year probability of pregnancy. We compared 1-year probability of pregnancy after intended postplacental or intended delayed postpartum IUD placement. We obtained estimates from the literature for the proportions of the following: mode of delivery, successful IUD placement, IUD type, postpartum visit attendance, IUD expulsion, IUD discontinuation, and contraceptive use, choice, and efficacy after IUD discontinuation. We performed sensitivity analyses and a Monte Carlo simulation to account for variations in proportion estimates. RESULTS:One-year probabilities of pregnancy among a theoretical cohort of 2,500,000 women intending to receive a postplacental IUD after vaginal birth and 1,250,000 women intending to receive a postplacental IUD after cesarean birth were 17.3% and 11.2%, respectively; the 1-year probability of pregnancy among a theoretical cohort of 2,500,000 women intending to receive a delayed postpartum IUD was 24.6%. For delayed postpartum IUD placement to have effectiveness equal to postplacental placement, 91.4% of women delivering vaginally and 99.7% of women delivering by cesarean would need to attend postpartum care. Once placed, the effectiveness of postplacental IUDs was lower than that of delayed postpartum IUDs: 1-year probabilities of pregnancy after IUD placement at a vaginal birth, cesarean birth, and an outpatient postpartum visit were 15.4%, 6.6%, and 3.9%, respectively. CONCLUSION:After accounting for factors that affect successful IUD placement and retention, this decision model indicates that intended postplacental IUD insertion results in a lower 1-year probability of pregnancy as compared with intended delayed postpartum IUD insertion.

SUBMITTER: Sonalkar S 

PROVIDER: S-EPMC6328318 | biostudies-literature | 2018 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

A Decision Analysis Model of 1-Year Effectiveness of Intended Postplacental Compared With Intended Delayed Postpartum Intrauterine Device Insertion.

Sonalkar Sarita S   Hunter Tegan T   Gurney Elizabeth P EP   McAllister Arden A   Schreiber Courtney A CA  

Obstetrics and gynecology 20181101 5


<h4>Objective</h4>To compare, using decision analysis methodology, the 1-year probability of pregnancy after intended postplacental intrauterine device (IUD) insertion with intended delayed insertion at an outpatient postpartum visit (delayed postpartum placement).<h4>Methods</h4>We developed an evidence-based decision model with the primary outcome of 1-year probability of pregnancy. We compared 1-year probability of pregnancy after intended postplacental or intended delayed postpartum IUD plac  ...[more]

Similar Datasets

| S-EPMC3202348 | biostudies-literature
| S-EPMC3104850 | biostudies-literature
| S-EPMC9898742 | biostudies-literature
| S-EPMC8886522 | biostudies-literature
| S-EPMC6351181 | biostudies-literature
| S-EPMC6040814 | biostudies-literature
| S-EPMC7644571 | biostudies-literature
| S-EPMC6467543 | biostudies-literature
| S-EPMC6734494 | biostudies-literature
| S-EPMC10031390 | biostudies-literature