Unknown

Dataset Information

0

Value of three-dimensional endoanal ultrasound scan (3D-EAUS) in preoperative assessment of fistula-in-ano.


ABSTRACT: OBJECTIVE:The aim of this study was to determine the accuracy of three-dimensional endoanal ultrasound scan (3D-EAUS) in the pre-operative assessment of fistula-in-ano in identifying the fistula tract and comparing with findings at surgery in a South Asian cohort. A retrospective analysis of 87 patients with suspected fistula-in-ano who underwent pre-operative 3D-EAUS between January 2009 and January 2016 was carried out. All patients subsequently had surgical exploration under anaesthesia (EUA), irrespective of 3D-EAUS findings. The 3D-EAUS results were compared with the surgical findings to determine the accuracy of 3D-EAUS. RESULTS:A total of 86 (98.9%) patients (male?=?75) were subsequently shown to have a fistula at surgical exploration and of them, 3D-EAUS detected a fistula in 79 (92%) patients. In this cohort, 3D-EAUS correctly predicted the surgical findings in (n?=?61, 70.9%) patients with the highest accuracy being for transphincteric fistulae (87.1%). However, the overall concordance in our study was low with a kappa coefficient of 0.318. Additional findings such as sphincter defects were detected by the 3D-EAUS in 37 patients (internal sphincter defects-21, external sphincter defects-7, both-9) which were not evident at EUA. Therefore, 3D-EAUS had a good accuracy in selected types of fistulae and particularly useful in identifying sphincter defects before surgery.

SUBMITTER: Almeida IS 

PROVIDER: S-EPMC6352344 | biostudies-literature | 2019 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Value of three-dimensional endoanal ultrasound scan (3D-EAUS) in preoperative assessment of fistula-in-ano.

Almeida Isuru Sampath IS   Jayarajah Umesh U   Wickramasinghe Dakshitha Praneeth DP   Samarasekera Dharmabandhu Nandadeva DN  

BMC research notes 20190129 1


<h4>Objective</h4>The aim of this study was to determine the accuracy of three-dimensional endoanal ultrasound scan (3D-EAUS) in the pre-operative assessment of fistula-in-ano in identifying the fistula tract and comparing with findings at surgery in a South Asian cohort. A retrospective analysis of 87 patients with suspected fistula-in-ano who underwent pre-operative 3D-EAUS between January 2009 and January 2016 was carried out. All patients subsequently had surgical exploration under anaesthes  ...[more]

Similar Datasets

| S-EPMC11318121 | biostudies-literature
| S-EPMC2642857 | biostudies-other
| S-EPMC8246180 | biostudies-literature
| S-EPMC4607815 | biostudies-literature
| S-EPMC7090348 | biostudies-literature
| S-EPMC9338380 | biostudies-literature
| S-EPMC7879177 | biostudies-literature
| S-EPMC5181383 | biostudies-literature
| S-EPMC10451941 | biostudies-literature