Unknown

Dataset Information

0

Measurement properties of the OARSI core set of performance-based measures for hip osteoarthritis: a prospective cohort study on reliability, construct validity and responsiveness in 90 hip osteo-arthritis patients.


ABSTRACT: Background and purpose - Improvement of physical function is one of the main treatment goals in severe hip osteoarthritis (OA) patients. The Osteoarthritis Research Society International (OARSI) has identified a core set of performance-based tests to assess the construct physical function: 30-s chair stand test (30-s CST), 4x10-meter fast-paced walk test (40 m FPWT), and a stair-climb test. Despite this recommendation, available evidence on the measurement properties is limited. We evaluated the reliability, validity, and responsiveness of these performance-based measures in patients with hip OA scheduled for total hip arthroplasty (THA). Patients and methods - Baseline and 12-month follow-up measurements were prospectively obtained in 90 end-stage hip OA patients who underwent THA. As there is no gold standard for comparison, the hypothesis testing method was used for construct validity and responsiveness analysis. A test can be assumed valid if ?75% of predefined hypotheses are confirmed. A subgroup (n = 30) underwent test-retest measurements for reliability analysis. The Oxford Hip Score, Hip injury and Osteoarthritis Outcome Score-Physical Function Short Form, pain during activity score, and muscle strength were used as comparator instruments. Results - Test-retest reliability was appropriate; intraclass correlation coefficient values exceeded 0.70 for all 3 tests. None of the performance-based measures reached 75% hypothesis confirmation for the construct validity or responsiveness analysis. Interpretation - The performance-based tests have good reliability in the assessment of physical function. Construct validity and responsiveness, using patient-reported measures and muscle strength as comparator instruments, could not be confirmed. Therefore, our findings do not justify their use for clinical practice.

SUBMITTER: Tolk JJ 

PROVIDER: S-EPMC6366472 | biostudies-literature | 2019 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Measurement properties of the OARSI core set of performance-based measures for hip osteoarthritis: a prospective cohort study on reliability, construct validity and responsiveness in 90 hip osteo-arthritis patients.

Tolk Jaap J JJ   Janssen Rob P A RPA   Prinsen C Sanna A C CSAC   van der Steen M Marieke C MMC   Bierma Zeinstra Sita M A SMA   Reijman Max M  

Acta orthopaedica 20181119 1


Background and purpose - Improvement of physical function is one of the main treatment goals in severe hip osteoarthritis (OA) patients. The Osteoarthritis Research Society International (OARSI) has identified a core set of performance-based tests to assess the construct physical function: 30-s chair stand test (30-s CST), 4x10-meter fast-paced walk test (40 m FPWT), and a stair-climb test. Despite this recommendation, available evidence on the measurement properties is limited. We evaluated the  ...[more]

Similar Datasets

| S-EPMC8033700 | biostudies-literature
| S-EPMC10811766 | biostudies-literature
| S-EPMC2756618 | biostudies-literature
| S-EPMC8855541 | biostudies-literature
| S-EPMC6649670 | biostudies-literature
| S-EPMC5964707 | biostudies-literature
| S-EPMC6482597 | biostudies-literature
| S-EPMC8361683 | biostudies-literature
| S-EPMC1754907 | biostudies-literature
| S-EPMC9326373 | biostudies-literature