Unknown

Dataset Information

0

Optical coherence tomographic analysis of drug-eluting in-stent restenosis at different times: A STROBE compliant study.


ABSTRACT: The imaging characteristics of drug-eluting in-stent restenosis (ISR) at different times varied; however, the mechanism had not yet been elucidated.To analyze the imaging characteristics of drug-eluting ISR at different time points by optical coherence tomography (OCT) and investigate the cause of the stent treatment failure.A total of 70 patients with drug-eluting ISR undergoing OCT were enrolled (intimal hyperplasia ?50% of stent area) and implanted with drug-eluting stents. According to stent implantation time, the patients were divided into 2 groups: early in-stent restenosis group (E-ISR group) (group A, n?=?35, stent age ?12 months) and late in-stent restenosis group (L-ISR group) (group B, n?=?35, stent age ?24 months). A qualitative analysis of the restenosis tissue included the nature of restenosis tissue (homogeneous and heterogeneous), neoatherosclerosis, thin-cap fibroatheroma (TCFA), and microvessels.The ratio of ?75% cross-sectional area stenosis between the L-ISR and E-ISR groups was (60.00% vs 34.28%, P?

SUBMITTER: Feng C 

PROVIDER: S-EPMC6372013 | biostudies-literature | 2018 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Optical coherence tomographic analysis of drug-eluting in-stent restenosis at different times: A STROBE compliant study.

Feng Chunguang C   Zhang Peiying P   Han Bing B   Li Xianchi X   Liu Yi Y   Niu Dongdong D   Shi Yibing Y  

Medicine 20180801 34


The imaging characteristics of drug-eluting in-stent restenosis (ISR) at different times varied; however, the mechanism had not yet been elucidated.To analyze the imaging characteristics of drug-eluting ISR at different time points by optical coherence tomography (OCT) and investigate the cause of the stent treatment failure.A total of 70 patients with drug-eluting ISR undergoing OCT were enrolled (intimal hyperplasia ≥50% of stent area) and implanted with drug-eluting stents. According to stent  ...[more]

Similar Datasets

| S-EPMC8728720 | biostudies-literature
| S-EPMC6265391 | biostudies-literature
| S-EPMC5533030 | biostudies-literature
| S-EPMC8568188 | biostudies-literature
| S-EPMC3740196 | biostudies-literature
| S-EPMC4866458 | biostudies-literature
| S-EPMC5506705 | biostudies-other
| S-EPMC8164007 | biostudies-literature
| S-EPMC4552606 | biostudies-literature