Novel spiral mapping catheter facilitates observation of the time-to-pulmonary vein isolation during cryoballoon ablation.


ABSTRACT: Observation of the time-to-pulmonary vein isolation (TTI) by a spiral mapping catheter has emerged as a valuable procedural parameter in cryoballoon pulmonary vein isolation (PVI). The 1st generation spiral mapping catheter (Achieve, SMC1) has been available as an 8-polar catheter with a distal loop diameter of 15 or 20 mm. The novel spiral mapping catheter (Achieve Advance, SMC2) was designed as a true guidewire and is available, in addition to the sizes of the SMC1, as a 10-polar mapping catheter with a distal loop diameter of 25 mm. Whether these novel features of SMC2 influence procedural characteristics of Cryo-PVI in comparison to SMC1 has not been reported. In this prospective cohort study 158 patients (age 65.1?±?12.4 years, female 39%, paroxysmal AF 60%) undergoing PVI with the 2nd generation cryoballoon were included. SMC1 was used in 57 patients (36%), whereas 101 patients (64%) underwent Cryo-PVI with the SMC2. All PVs (623/623, 100%) were isolated successfully. Mean procedure duration was 72.0?±?18.9 min in the SMC1 group and 74.4?±?19.1 min in the SMC2 group (p?=?0.432). Mean fluoroscopy time was also not different between both study groups (SMC1 15.7?±?6.6 min, SMC2 15.7?±?7.3 min, p?=?0.593). TTI was observed in 68.6% of pulmonary veins in the SMC1 group, whereas TTI observation rate was 82.6% in the SMC2 group (p?

SUBMITTER: Pott A 

PROVIDER: S-EPMC6373539 | biostudies-literature | 2019 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Novel spiral mapping catheter facilitates observation of the time-to-pulmonary vein isolation during cryoballoon ablation.

Pott Alexander A   Petscher Kerstin K   Baumhardt Michael M   Stephan Tilman T   Rattka Manuel M   Paliskyte Rima R   Bothner Carlo C   Keßler Mirjam M   Rottbauer Wolfgang W   Dahme Tillman T  

Heart and vessels 20181009 3


Observation of the time-to-pulmonary vein isolation (TTI) by a spiral mapping catheter has emerged as a valuable procedural parameter in cryoballoon pulmonary vein isolation (PVI). The 1st generation spiral mapping catheter (Achieve, SMC1) has been available as an 8-polar catheter with a distal loop diameter of 15 or 20 mm. The novel spiral mapping catheter (Achieve Advance, SMC2) was designed as a true guidewire and is available, in addition to the sizes of the SMC1, as a 10-polar mapping cathe  ...[more]

Similar Datasets

| S-EPMC6495074 | biostudies-literature
| S-EPMC8174287 | biostudies-literature
| S-EPMC7501890 | biostudies-literature
| S-EPMC9681817 | biostudies-literature
| S-EPMC7524096 | biostudies-literature
| S-EPMC10241727 | biostudies-literature
| S-EPMC3938670 | biostudies-literature
| S-EPMC9733956 | biostudies-literature
| S-EPMC7252765 | biostudies-literature
| S-EPMC8815090 | biostudies-literature