Minimal force transmission between human thumb and index finger muscles under passive conditions.
Ontology highlight
ABSTRACT: It has been hypothesized that force can be transmitted between adjacent muscles. Intermuscle force transmission violates the assumption that muscles act in mechanical isolation, and implies that predictions from biomechanical models are in error due to mechanical interactions between muscles, but the functional relevance of intermuscle force transmission is unclear. To investigate intermuscle force transmission between human flexor pollicis longus and the index finger part of flexor digitorum profundus, we compared finger flexion force produced by passive thumb flexion after one of three conditioning protocols: passive thumb flexion-extension cycling, thumb flexion maximal voluntary contraction (MVC), and thumb extension stretch. Finger flexion force increased after all three conditions. Compared to passive thumb flexion-extension cycling, change in finger flexion force was less after thumb extension stretch (mean difference 0.028 N, 95% CI 0.005 to 0.051 N), but not after thumb flexion MVC (0.007 N, 95% CI -0.020 to 0.033 N). As muscle conditioning changed finger flexion force produced by passive thumb flexion, the change in force is likely due to intermuscle force transmission. Thus, intermuscle force transmission resulting from passive stretch of an adjacent muscle is probably small enough to be ignored.
SUBMITTER: Diong J
PROVIDER: S-EPMC6377133 | biostudies-literature | 2019
REPOSITORIES: biostudies-literature
ACCESS DATA