Automatic segmentation of cardiac substructures from noncontrast CT images: accurate enough for dosimetric analysis?


ABSTRACT: PURPOSE:We evaluated the feasibility of using an automatic segmentation tool to delineate cardiac substructures from noncontrast computed tomography (CT) images for cardiac dosimetry and toxicity analyses for patients with nonsmall cell lung cancer (NSCLC) after radiotherapy. MATERIAL AND METHODS:We used an in-house developed multi-atlas segmentation tool to delineate 11cardiac substructures, including the whole heart, four heart chambers, and six greater vessels, automatically from the averaged 4D-CT planning images of 49 patients with NSCLC. Two experienced radiation oncologists edited the auto-segmented contours. Times for automatic segmentation and modification were recorded. The modified contours were compared with the auto-segmented contours in terms of Dice similarity coefficient (DSC) and mean surface distance (MSD) to evaluate the extent of modification. Differences in dose-volume histogram (DVH) characteristics were also evaluated for the modified versus auto-segmented contours. RESULTS:The mean automatic segmentation time for all 11 structures was 7-9?min. For the 49 patients, the mean DSC values (±SD) ranged from .73?±?.08 to .95?±?.04, and the mean MSD values ranged from 1.3?±?.6?mm to 2.9?±?5.1?mm. Overall, the modifications were small; the largest modifications were in the pulmonary vein and the inferior vena cava. The heart V30 (volume receiving dose ?30?Gy) and the mean dose to the whole heart and the four heart chambers were not different for the modified versus the auto-segmented contours based on the statistically significant condition of p?

SUBMITTER: Luo Y 

PROVIDER: S-EPMC6377299 | biostudies-literature | 2019 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Automatic segmentation of cardiac substructures from noncontrast CT images: accurate enough for dosimetric analysis?

Luo Yangkun Y   Xu Yujin Y   Liao Zhongxing Z   Gomez Daniel D   Wang Jingqian J   Jiang Wei W   Zhou Rongrong R   Williamson Ryan R   Court Laurence E LE   Yang Jinzhong J  

Acta oncologica (Stockholm, Sweden) 20181011 1


<h4>Purpose</h4>We evaluated the feasibility of using an automatic segmentation tool to delineate cardiac substructures from noncontrast computed tomography (CT) images for cardiac dosimetry and toxicity analyses for patients with nonsmall cell lung cancer (NSCLC) after radiotherapy.<h4>Material and methods</h4>We used an in-house developed multi-atlas segmentation tool to delineate 11cardiac substructures, including the whole heart, four heart chambers, and six greater vessels, automatically fr  ...[more]

Similar Datasets

| S-EPMC5292289 | biostudies-literature
| S-EPMC8131193 | biostudies-literature
| S-EPMC7307704 | biostudies-literature
| S-EPMC6402577 | biostudies-literature
| S-EPMC10391673 | biostudies-literature
| S-EPMC8476971 | biostudies-literature
| S-EPMC9018763 | biostudies-literature
| S-EPMC10799452 | biostudies-literature
| S-EPMC10788793 | biostudies-literature
| S-EPMC7543739 | biostudies-literature