Label free thrombin detection in presence of high concentration of albumin using an aptamer-functionalized nanoporous membrane.


ABSTRACT: Nanoporous alumina membranes have become a ubiquitous biosensing platform for a variety of applications and aptamers are being increasingly utilized as recognition elements in protein sensing devices. Combining the advantages of the two, we report label-free sensitive detection of human ?-thrombin by an aptamer-functionalized nanoporous alumina membrane using a four-electrode electrochemical cell. The sensor response to ?-thrombin was determined in the presence of a high concentration (500??M) of human serum albumin (HSA) as an interfering protein in the background. The sensor sensitivity was also characterized against ?-thrombin, which is a modified ?-thrombin lacking the aptamer binding epitope. The detection limit, within an appreciable signal/noise ratio, was 10?pM of ?-thrombin in presence of 500??M HSA. The proposed scheme involves the use of minimum reagents/sample preparation steps, has appreciable response in presence of high concentrations of interfering molecules and is readily amenable to miniaturization by association with existing-chip based electrical systems for application in point-of-care diagnostic devices.

SUBMITTER: Gosai A 

PROVIDER: S-EPMC6383723 | biostudies-literature | 2019 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Label free thrombin detection in presence of high concentration of albumin using an aptamer-functionalized nanoporous membrane.

Gosai Agnivo A   Hau Yeah Brendan Shin BS   Nilsen-Hamilton Marit M   Shrotriya Pranav P  

Biosensors & bioelectronics 20181018


Nanoporous alumina membranes have become a ubiquitous biosensing platform for a variety of applications and aptamers are being increasingly utilized as recognition elements in protein sensing devices. Combining the advantages of the two, we report label-free sensitive detection of human α-thrombin by an aptamer-functionalized nanoporous alumina membrane using a four-electrode electrochemical cell. The sensor response to α-thrombin was determined in the presence of a high concentration (500 μM) o  ...[more]

Similar Datasets

| S-EPMC3120900 | biostudies-literature
| S-EPMC6833485 | biostudies-literature
| S-EPMC7023026 | biostudies-literature
| S-EPMC9654754 | biostudies-literature
| S-EPMC6315524 | biostudies-other
| S-EPMC10216731 | biostudies-literature
| S-EPMC2651834 | biostudies-literature
| S-EPMC3388206 | biostudies-literature
| S-EPMC3177225 | biostudies-literature
| S-EPMC2821951 | biostudies-literature