Chartis Measurement of Collateral Ventilation: Conscious Sedation versus General Anesthesia - A Retrospective Comparison.


ABSTRACT: BACKGROUND:Absence of interlobar collateral ventilation using the Chartis measurement is the key predictor for successful endobronchial valve treatment in severe emphysema. Chartis was originally validated in spontaneous breathing patients under conscious sedation (CS); however, this can be challenging due to cough, mucus secretion, mucosal swelling, and bronchoconstriction. Performing Chartis under general anesthesia (GA) avoids these problems and may result in an easier procedure with a higher success rate. However, using Chartis under GA with positive pressure ventilation has not been validated. OBJECTIVES:In this study we investigated the impact of anesthesia technique, CS versus GA, on the feasibility and outcomes of Chartis measurement. METHODS:We retrospectively analyzed all Chartis measurements performed at our hospital from October 2010 until December 2017. RESULTS:We analyzed 250 emphysema patients (median forced expiratory volume in 1 s 26%, range 12-52% predicted). In 121 patients (48%) the measurement was performed using CS, in 124 (50%) using GA, and in 5 (2%) both anesthesia techniques were used. In total, 746 Chartis readings were analyzed (432 CS, 277 GA, and 37 combination). Testing under CS took significantly longer than GA (median 19 min [range 5-65] vs. 11 min [3-35], p < 0.001) and required more measurements (3 [1-13] vs. 2 [1-6], p < 0.001). There was no significant difference in target lobe volume reduction after treatment (-1,123 mL [-3,604 to 332] in CS vs. -1,251 mL [-3,333 to -1] in GA, p = 0.35). CONCLUSIONS:In conclusion, Chartis measurement under CS took significantly longer and required more measurements than under GA, without a difference in treatment outcome. We recommend a prospective trial comparing both techniques within the same patients to validate this approach.

SUBMITTER: Welling JBA 

PROVIDER: S-EPMC6390462 | biostudies-literature | 2018

REPOSITORIES: biostudies-literature

altmetric image

Publications

Chartis Measurement of Collateral Ventilation: Conscious Sedation versus General Anesthesia - A Retrospective Comparison.

Welling Jorrit B A JBA   Hartman Jorine E JE   Ten Hacken Nick H T NHT   Franz Ina I   Charbonnier Jean-Paul JP   van Rikxoort Eva M EM   Kerstjens Huib A M HAM   Klooster Karin K   Slebos Dirk-Jan DJ  

Respiration; international review of thoracic diseases 20180816 5


<h4>Background</h4>Absence of interlobar collateral ventilation using the Chartis measurement is the key predictor for successful endobronchial valve treatment in severe emphysema. Chartis was originally validated in spontaneous breathing patients under conscious sedation (CS); however, this can be challenging due to cough, mucus secretion, mucosal swelling, and bronchoconstriction. Performing Chartis under general anesthesia (GA) avoids these problems and may result in an easier procedure with  ...[more]

Similar Datasets

| S-EPMC7900389 | biostudies-literature
| S-EPMC6992433 | biostudies-literature
| S-EPMC7650030 | biostudies-literature
| S-EPMC6511209 | biostudies-literature
| S-EPMC10999759 | biostudies-literature
| S-EPMC7960428 | biostudies-literature
| S-EPMC8013063 | biostudies-literature
| S-EPMC6262282 | biostudies-literature
| S-EPMC6645641 | biostudies-literature
| S-EPMC10069205 | biostudies-literature