Long-term patency and clinical outcome of the transjugular intrahepatic portosystemic shunt using the expanded polytetrafluoroethylene stent-graft.


ABSTRACT: BACKGROUND:Transjugular intrahepatic portosystemic shunt (TIPS) creation is an established treatment option to management the complications of portal hypertension. Recent data on the long-term outcomes of TIPS are scarce. MATERIALS AND METHODS:In this single-institution retrospective study, 495 patients underwent TIPS with the Fluency stent-grafts between December 2011 and June 2015 were evaluated. The cumulative rates of TIPS dysfunction, hepatic encephalopathy (HE), survival, and variceal rebleeding were determined using the Kaplan-Meier method. Cox regression analysis was used to assess the parameters on TIPS patency, occurrence of HE and all-cause mortality. RESULTS:Technical success was 98.2%. TIPS-related complications occurred in 67 patients (13.5%) during the index hospital stay. TIPS creation resulted in an immediate decrease in mean portosystemic pressure gradient from 23.4 ± 7.1 mmHg to 7.6 ± 3.5 mmHg. The median follow-up period was 649 days. Primary TIPS patency rates were 93%, and 75.9% at 1 and 3 years, respectively. Previous splenectomy was associated with a higher risk of TPS dysfunction. The cumulative survival rates were 93.4% and 77.2% at 1 and 3 years, respectively. The 1- and 3-year probability of remaining free of variceal bleeding rates were 94.2% and 71.4%, respectively. CONCLUSIONS:This retrospective single-center experience with TIPS using the Fluency stent-grafts demonstrates good long-term patency and favorable good clinical results. Previous splenectomy strongly predicts shunt dysfunction.

SUBMITTER: Luo X 

PROVIDER: S-EPMC6392293 | biostudies-literature | 2019

REPOSITORIES: biostudies-literature

altmetric image

Publications

Long-term patency and clinical outcome of the transjugular intrahepatic portosystemic shunt using the expanded polytetrafluoroethylene stent-graft.

Luo Xuefeng X   Zhao Ming M   Wang Xiaoze X   Jiang Mingshan M   Yu Jiaze J   Li Xiao X   Yang Li L  

PloS one 20190227 2


<h4>Background</h4>Transjugular intrahepatic portosystemic shunt (TIPS) creation is an established treatment option to management the complications of portal hypertension. Recent data on the long-term outcomes of TIPS are scarce.<h4>Materials and methods</h4>In this single-institution retrospective study, 495 patients underwent TIPS with the Fluency stent-grafts between December 2011 and June 2015 were evaluated. The cumulative rates of TIPS dysfunction, hepatic encephalopathy (HE), survival, an  ...[more]

Similar Datasets

| S-EPMC8216680 | biostudies-literature
| S-EPMC9248993 | biostudies-literature
| S-EPMC4447874 | biostudies-other
| S-EPMC1727497 | biostudies-other
| S-EPMC4139433 | biostudies-other
| S-EPMC5209675 | biostudies-literature
| S-EPMC7685811 | biostudies-literature
| S-EPMC7841802 | biostudies-literature
| S-EPMC8209000 | biostudies-literature