Unknown

Dataset Information

0

Comparing the diagnostic performance of radiation dose-equivalent radiography, multi-detector computed tomography and cone beam computed tomography for finger fractures - A phantom study.


ABSTRACT: PURPOSE:To compare the diagnostic performance and raters´confidence of radiography, radiography equivalent dose multi-detector computed tomography (RED-MDCT) and radiography equivalent dose cone beam computed tomography (RED-CBCT) for finger fractures. METHODS:Fractures were inflicted artificially and randomly to 10 cadaveric hands of body donors. Radiography as well as RED-MDCT and RED-CBCT imaging were performed at dose settings equivalent to radiography. Images were de-identified and analyzed by three radiologists regarding finger fractures, joint involvement and confidence with their findings. Reference standard was consensus reading by two radiologists of the fracturing protocol and high-dose multi-detector computed tomography (MDCT) images. Sensitivity and specificity were calculated and compared with Cochrane´s Q and post hoc analysis. Rater´s confidence was calculated with Friedman Test and post hoc Nemenyi Test. RESULTS:Rater´s confidence, inter-rater correlation, specificity for fractures and joint involvement were higher in RED-MDCT and RED-CBCT compared to radiography. No differences between the modalities were found regarding sensitivity. CONCLUSION:In this phantom study, radiography equivalent dose computed tomography (RED-CT) demonstrates a partly higher diagnostic accuracy than radiography. Implementing RED-CT in the diagnostic work-up of finger fractures could improve diagnostics, support correct classification and adequate treatment. Clinical studies should be performed to confirm these preliminary results.

SUBMITTER: Reidelbach CS 

PROVIDER: S-EPMC6400385 | biostudies-literature | 2019

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparing the diagnostic performance of radiation dose-equivalent radiography, multi-detector computed tomography and cone beam computed tomography for finger fractures - A phantom study.

Reidelbach Carolin Sophie CS   Goerke Sebastian Moritz SM   Leschka Simon Carl SC   Neubauer Claudia C   Soschynski Martin M   Lampert Florian F   Zajonc Horst H   Kotter Elmar E   Langer Mathias M   Neubauer Jakob J  

PloS one 20190305 3


<h4>Purpose</h4>To compare the diagnostic performance and raters´confidence of radiography, radiography equivalent dose multi-detector computed tomography (RED-MDCT) and radiography equivalent dose cone beam computed tomography (RED-CBCT) for finger fractures.<h4>Methods</h4>Fractures were inflicted artificially and randomly to 10 cadaveric hands of body donors. Radiography as well as RED-MDCT and RED-CBCT imaging were performed at dose settings equivalent to radiography. Images were de-identifi  ...[more]

Similar Datasets

| S-EPMC5722599 | biostudies-literature
| S-EPMC6332966 | biostudies-literature
| S-EPMC8133899 | biostudies-literature
| S-EPMC7415745 | biostudies-literature
| S-EPMC6805882 | biostudies-literature
| S-EPMC8584471 | biostudies-literature
| S-EPMC4032412 | biostudies-other