Unknown

Dataset Information

0

Diagnostic Performance of Measurement of Fecal Elastase-1 in Detection of Exocrine Pancreatic Insufficiency: Systematic Review and Meta-analysis.


ABSTRACT: BACKGROUND & AIMS:Tests to quantify fecal levels of chymotrypsin like elastase family member 3 (CELA3 or elastase-1) in feces are widely used to identify patients with exocrine pancreatic insufficiency (EPI). However, the diagnostic accuracy of this test, an ELISA, is not clear. We performed a systematic review and meta-analysis to determine the accuracy of measurement of fecal elastase-1 in detection of EPI. METHODS:We searched PubMed, Embase, and reference lists for articles through November 2016 describing studies that compared fecal level of elastase-1 with results from a reference standard, direct method (secretin stimulation test), or indirect method (measurement of fecal fat) for detection of EPI. Sensitivity and specificity values were pooled statistically using bivariate diagnostic meta-analysis. RESULTS:We included total of 428 cases of EPI and 673 individuals without EPI (controls), from 14 studies, in the meta-analysis. The assay for elastase-1, compared to secretin stimulation test, identified patients with pancreatic insufficiency with a pooled sensitivity value of 0.77 (95% CI, 0.58-0.89) and specificity value of 0.88 (95% CI, 0.78-0.93). In an analysis of 345 cases of EPI and 312 controls, from 6 studies, the fecal elastase-1 assay identified patients with EPI with a pooled sensitivity value of 0.96 (95% CI, 0.79-0.99) and specificity value of 0.88 (95% CI, 0.59-0.97), compared to quantitative fecal fat estimation. In patients with low pre-test probability of EPI (5%), the fecal elastase-1 assay would have a false-negative rate of 1.1% and a false-positive rate of 11%, indicating a high yield in ruling out EPI but not in detection of EPI. In contrast, in patients with high pre-test probability of EPI (40%), approximately 10% of patients with EPI would be missed (false negatives). CONCLUSIONS:In a systematic review and meta-analysis of studies that compared fecal level of elastase-1 for detection of EPI, we found that normal level of elastase-1 (above 200 mcg/g) can rule out EPI in patients with a low probability of this disorder (such as those with irritable bowel syndrome with diarrhea). However, in these patients, an abnormal level of elastase-1 (below 200 mcg/g) has a high false-positive rate.

SUBMITTER: Vanga RR 

PROVIDER: S-EPMC6402774 | biostudies-literature | 2018 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Diagnostic Performance of Measurement of Fecal Elastase-1 in Detection of Exocrine Pancreatic Insufficiency: Systematic Review and Meta-analysis.

Vanga Rohini R RR   Tansel Aylin A   Sidiq Saad S   El-Serag Hashem B HB   Othman Mohamed O MO  

Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association 20180131 8


<h4>Background & aims</h4>Tests to quantify fecal levels of chymotrypsin like elastase family member 3 (CELA3 or elastase-1) in feces are widely used to identify patients with exocrine pancreatic insufficiency (EPI). However, the diagnostic accuracy of this test, an ELISA, is not clear. We performed a systematic review and meta-analysis to determine the accuracy of measurement of fecal elastase-1 in detection of EPI.<h4>Methods</h4>We searched PubMed, Embase, and reference lists for articles thr  ...[more]

Similar Datasets

| S-EPMC6710758 | biostudies-literature
| S-EPMC6584228 | biostudies-literature
| S-EPMC7724551 | biostudies-literature
| S-EPMC4155341 | biostudies-literature
| S-EPMC406522 | biostudies-literature
| S-EPMC7509408 | biostudies-literature
| S-EPMC8483406 | biostudies-literature
| S-EPMC8121049 | biostudies-literature
| S-EPMC5495912 | biostudies-literature
| S-EPMC3654556 | biostudies-literature