Ontology highlight
ABSTRACT: Background
Studies have shown that overnight closed-loop insulin delivery can improve glucose control and reduce the risk of hypoglycemia and hence may improve metabolic outcomes and reduce burden for children with type 1 diabetes and their families. However, research so far has not reported insulin levels while comparing closed-loop to open-loop insulin delivery in children. Therefore, in this study we obtained glucose levels as well as plasma insulin levels in children with type 1 diabetes to evaluate the efficacy of a model-based closed-loop algorithm compared to an open-loop administration.Methods
Fifteen children with type 1 diabetes, 6-12 years, participated in this open-label single center study. We used a randomized cross over design in which we compared overnight closed-loop insulin delivery with sensor augmented pump therapy for two nights in both the hospital and at home (i.e., 1 night in-patient stay and at home per treatment condition). Only during the in-patient stay, hourly plasma insulin and blood glucose levels were assessed and are reported in this paper.Results
Results of paired sample t-tests revealed that although plasma insulin levels were significantly lower during the closed-loop than in the open-loop (Mean difference 36.51 pmol/l; t(13) = 2.13, p = .03, effect size d = 0.57), blood glucose levels did not vary between conditions (mean difference 0.76 mmol/l; t(13) = 1.24, p = .12, d = 0.37). The administered dose of insulin was significantly lower during the closed-loop compared with the open-loop (mean difference 0.10 UI; t(12) = 2.45, p = .02, d = 0.68).Conclusions
Lower insulin doses were delivered in the closed-loop, resulting in lower plasma insulin levels, whereby glucose levels were not affected negatively. This suggests that the closed-loop administration is better targeted and hence could be more effective.
SUBMITTER: Schierloh U
PROVIDER: S-EPMC6408001 | biostudies-literature | 2019
REPOSITORIES: biostudies-literature
Schierloh Ulrike U Wilinska Malgorzata E ME Pit-Ten Cate Ineke M IM Baumann Petra P Hovorka Roman R De Beaufort Carine C
PloS one 20190308 3
<h4>Background</h4>Studies have shown that overnight closed-loop insulin delivery can improve glucose control and reduce the risk of hypoglycemia and hence may improve metabolic outcomes and reduce burden for children with type 1 diabetes and their families. However, research so far has not reported insulin levels while comparing closed-loop to open-loop insulin delivery in children. Therefore, in this study we obtained glucose levels as well as plasma insulin levels in children with type 1 diab ...[more]