Unknown

Dataset Information

0

The Ewing Amputation: The First Human Implementation of the Agonist-Antagonist Myoneural Interface.


ABSTRACT: Background:The agonist-antagonist myoneural interface (AMI) comprises a surgical construct and neural control architecture designed to serve as a bidirectional interface, capable of reflecting proprioceptive sensation of prosthetic joint position, speed, and torque from and advanced limb prosthesis onto the central nervous system. The AMI surgical procedure has previously been vetted in animal models; we here present the surgical results of its translation to human subjects. Methods:Modified unilateral below knee amputations were performed in the elective setting in 3 human subjects between July 2016 and April 2017. AMIs were constructed in each subject to control and interpret proprioception from the bionic ankle and subtalar joints. Intraoperative, perioperative, and postoperative residual-limb outcome measures were recorded and analyzed, including electromyographic and radiographic imaging of AMI musculature. Results:Mean subject age was 38?±?13 years, and mean body mass index was 29.5?±?5.5?kg/m2. Mean operative time was 346?±?87 minutes, including 120 minutes of tourniquet time per subject. Complications were minor and included transient cellulitis and one instance of delayed wound healing. All subjects demonstrated mild limb hypertrophy postoperatively, and intact construct excursion with volitional muscle activation. All patients reported a high degree of phantom limb position perception with no reports of phantom pain. Conclusions:The AMI offers the possibility of improved prosthetic control and restoration of muscle-tendon proprioception. Initial results in this first cohort of human patients are promising and provide evidence as to the potential role of AMIs in the care of patients requiring below knee amputation.

SUBMITTER: Clites TR 

PROVIDER: S-EPMC6414116 | biostudies-literature | 2018 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

The Ewing Amputation: The First Human Implementation of the Agonist-Antagonist Myoneural Interface.

Clites Tyler R TR   Herr Hugh M HM   Srinivasan Shriya S SS   Zorzos Anthony N AN   Carty Matthew J MJ  

Plastic and reconstructive surgery. Global open 20181116 11


<h4>Background</h4>The agonist-antagonist myoneural interface (AMI) comprises a surgical construct and neural control architecture designed to serve as a bidirectional interface, capable of reflecting proprioceptive sensation of prosthetic joint position, speed, and torque from and advanced limb prosthesis onto the central nervous system. The AMI surgical procedure has previously been vetted in animal models; we here present the surgical results of its translation to human subjects.<h4>Methods</  ...[more]

Similar Datasets

| S-EPMC7786239 | biostudies-literature
| S-EPMC6374452 | biostudies-literature
| S-EPMC7891024 | biostudies-literature
| S-EPMC9356003 | biostudies-literature
| S-EPMC4607565 | biostudies-literature
| S-EPMC7530068 | biostudies-literature
| S-EPMC3372726 | biostudies-literature
| S-EPMC4331004 | biostudies-literature
| S-EPMC2788680 | biostudies-literature
| S-EPMC3815160 | biostudies-literature