Unknown

Dataset Information

0

C-O Bond Dissociation and Induced Chemical Ionization Using High Energy (CO2)n+ Gas Cluster Ion Beam.


ABSTRACT: A gas cluster ion beam (GCIB) source, consisting of CO2 clusters and operating with kinetic energies of up to 60 keV, has been developed for the high resolution and high sensitivity imaging of intact biomolecules. The CO2 molecule is an excellent molecule to employ in a GCIB source due to its relative stability and improved focusing capabilities, especially when compared to the conventionally employed Ar cluster source. Here we report on experiments aimed to examine the behavior of CO2 clusters as they impact a surface under a variety of conditions. Clusters of (CO2)n+ (n =?2000~10,000) with varying sizes and kinetic energies were employed to interrogate both an organic and inorganic surface. The results show that C-O bond dissociation did not occur when the energy per molecule is less than 5 eV/n, but that oxygen adducts were seen in increasing intensity as the energy is above 5 eV/n, particularly, drastic enhancement up to 100 times of oxygen adducts was observed on Au surface. For Irganox 1010, an organic surface, oxygen containing adducts were observed with moderate signal enhancement. Molecular dynamics computer simulations were employed to test the hypothesis that the C-O bond is broken at high values of eV/n. These calculations show that C-O bond dissociation occurs at eV/n values less than the C-O bond energy (8.3 eV) by interaction with surface topological features. In general, the experiments suggest that the projectiles containing oxygen can enhance the ionization efficiency of surface molecules via chemically induced processes, and that CO2 can be an effective cluster ion source for SIMS experiments. Graphical Abstract.

SUBMITTER: Tian H 

PROVIDER: S-EPMC6417932 | biostudies-literature | 2019 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

C-O Bond Dissociation and Induced Chemical Ionization Using High Energy (CO<sub>2</sub>)<sub>n</sub><sup>+</sup> Gas Cluster Ion Beam.

Tian Hua H   Maciążek Dawid D   Postawa Zbigniew Z   Garrison Barbara J BJ   Winograd Nicholas N  

Journal of the American Society for Mass Spectrometry 20181114 3


A gas cluster ion beam (GCIB) source, consisting of CO<sub>2</sub> clusters and operating with kinetic energies of up to 60 keV, has been developed for the high resolution and high sensitivity imaging of intact biomolecules. The CO<sub>2</sub> molecule is an excellent molecule to employ in a GCIB source due to its relative stability and improved focusing capabilities, especially when compared to the conventionally employed Ar cluster source. Here we report on experiments aimed to examine the beh  ...[more]

Similar Datasets

| S-EPMC4089192 | biostudies-literature
| S-EPMC7293282 | biostudies-literature
| S-EPMC5199235 | biostudies-literature