A nanoliter resolution implantable micropump for murine inner ear drug delivery.


ABSTRACT: Advances in protective and restorative biotherapies have created new opportunities to use site-directed, programmable drug delivery systems to treat auditory and vestibular disorders. Successful therapy development that leverages the transgenic, knock-in, and knock-out variants of mouse models of human disease requires advanced microsystems specifically designed to function with nanoliter precision and with system volumes suitable for implantation. Here we present results for a novel biocompatible, implantable, scalable, and wirelessly controlled peristaltic micropump. The micropump configuration included commercially available catheter microtubing (250??m OD, 125??m ID) that provided a biocompatible leak-free flow path while avoiding complicated microfluidic interconnects. Peristaltic pumping was achieved by sequentially compressing the microtubing via expansion and contraction of a thermal phase-change material located in three chambers integrated adjacent to the microtubing. Direct-write micro-scale printing technology was used to build the mechanical components of the micropump around the microtubing directly on the back of a printed circuit board assembly (PCBA). The custom PCBA was fabricated using standard commercial processes providing microprocessor control of actuation and Bluetooth wireless communication through an Android application. The results of in vitro characterization indicated that nanoliter resolution control over the desired flow rates of 10-100?nL/min was obtained by changing the actuation frequency. Applying 10× greater than physiological backpressures and?±?3?°C ambient temperature variation did not significantly affect flow rates. Three different micropumps were tested on six mice for in vivo implantation of the catheter microtubing into the round window membrane niche for infusion of a known ototoxic compound (sodium salicylate) at 50?nL/min for 20?min. Real-time shifts in distortion product otoacoustic emission thresholds and amplitudes were measured during the infusion. There were systematic increases in distortion product threshold shifts during the 20-min perfusions; the mean shift was 15?dB for the most basal region. A biocompatibility study was performed to evaluate material suitability for chronic subcutaneous implantation and clinical translational development. The results indicated that the micropump components successfully passed key biocompatibility tests. A micropump prototype was implanted for one month without development of inflammation or infection. Although tested here on the small murine cochlea, this low-cost design and fabrication methodology is scalable for use in larger animals and for clinical applications in children and adults by appropriate scaling of the microtubing diameter and actuator volume.

SUBMITTER: Forouzandeh F 

PROVIDER: S-EPMC6424108 | biostudies-literature | 2019 Mar

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC3114251 | biostudies-literature
| S-EPMC2836414 | biostudies-literature
| S-EPMC5911243 | biostudies-literature
| S-EPMC6509234 | biostudies-literature
| S-EPMC10620978 | biostudies-literature
| S-EPMC7801246 | biostudies-literature
| S-EPMC6635812 | biostudies-literature
| S-EPMC4766044 | biostudies-literature
| S-EPMC8319626 | biostudies-literature
| S-EPMC8677643 | biostudies-literature