Validation of a novel stand-alone software tool for image guided cardiac catheter therapy.


ABSTRACT: Comparison of the targeting accuracy of a new software method for MRI-fluoroscopy guided endomyocardial interventions with a clinically available 3D endocardial electromechanical mapping system. The new CARTBox2 software enables therapy target selection based on infarction transmurality and local myocardial wall thickness deduced from preoperative MRI scans. The selected targets are stored in standard DICOM datasets. Fusion of these datasets with live fluoroscopy enables real-time visualization of MRI defined targets during fluoroscopy guided interventions without the need for external hardware. In ten pigs (60-75 kg), late gadolinium enhanced (LGE) MRI scans were performed 4 weeks after a 90-min LAD occlusion. Subsequently, 10-16 targeted fluorescent biomaterial injections were delivered in the infarct border zone (IBZ) using either the NOGA 3D-mapping system or CARTBox2. The primary endpoint was the distance of the injections to the IBZ on histology. Secondary endpoints were total procedure time, fluoroscopy time and dose, and the number of ventricular arrhythmias. The average distance of the injections to the IBZ was similar for CARTBox2 (0.5?±?3.2 mm) and NOGA (-?0.7?±?2.2 mm; p?=?0.52). Injection procedures with CARTBox2 and NOGA required 69?±?12 and 60?±?17 min, respectively (p?=?0.36). The required endocardial mapping procedure with NOGA prior to injections, leads to a significantly longer total procedure time (p?

SUBMITTER: van Es R 

PROVIDER: S-EPMC6428788 | biostudies-literature | 2019 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Validation of a novel stand-alone software tool for image guided cardiac catheter therapy.

van Es René R   van den Broek Hans T HT   van der Naald Mira M   de Jong Leon L   Nieuwenhuis Eliane R ER   Kraaijeveld Adriaan O AO   Doevendans Pieter A PA   Chamuleau Steven A J SAJ   van Slochteren Frebus J FJ  

The international journal of cardiovascular imaging 20190128 2


Comparison of the targeting accuracy of a new software method for MRI-fluoroscopy guided endomyocardial interventions with a clinically available 3D endocardial electromechanical mapping system. The new CARTBox2 software enables therapy target selection based on infarction transmurality and local myocardial wall thickness deduced from preoperative MRI scans. The selected targets are stored in standard DICOM datasets. Fusion of these datasets with live fluoroscopy enables real-time visualization  ...[more]

Similar Datasets

| S-EPMC9971291 | biostudies-literature
| PRJNA671252 | ENA
| S-EPMC4587797 | biostudies-literature
| S-EPMC5757220 | biostudies-literature
| S-EPMC9074202 | biostudies-literature
| S-EPMC8398665 | biostudies-literature
| S-EPMC10964252 | biostudies-literature
| S-EPMC6774505 | biostudies-literature
| S-EPMC8142495 | biostudies-literature
| S-EPMC7830157 | biostudies-literature