Project description:BackgroundThe short- and medium-term outcomes of iStent have been extensively studied; however, only few studies have investigated its long-term outcomes. Here, we assessed the long-term efficacy and safety of two iStents with concomitant cataract surgery in glaucomatous eyes while also evaluating measures of disease stability using visual field and optical coherence tomography (OCT) of the optic nerve and the macula throughout 8 years of follow-up.MethodsThis longitudinal, single-center consecutive case series included glaucomatous eyes that underwent implantation of two first-generation trabecular micro-bypass stents (iStent) with concomitant cataract surgery. Eight-year efficacy outcomes included mean intraocular pressure (IOP) and medications, as well as surgical success. Eight-year safety outcomes included best-corrected visual acuity (BCVA), visual field mean deviation (VF-MD), cup-to-disc ratio (CDR), retinal nerve fiber layer (RNFL) thickness, ganglion cell-inner plexiform layer (GC-IPL) thickness, and adverse events.ResultsA total of 62 eyes with primary open-angle glaucoma (POAG) were included. At 8 years postoperative, IOP reduced by 26% from 19.2 ± 3.9 mmHg preoperatively to 14.2 ± 2.4 mmHg (P < 0.001), 91.1% of eyes achieved IOP ≤ 18 mmHg (vs. 51.6% preoperatively), 69.6% of eyes achieved IOP ≤ 15 mmHg (vs. 14.5% preoperatively), and 25% of eyes achieved IOP ≤ 12 mmHg (vs. 1.6% preoperatively). Medication use decreased by 17.9% from 2.8 ± 1.1 preoperatively to 2.3 ± 1.2 (P = 0.018). Surgical success was 90%, as six eyes underwent subsequent glaucoma surgeries. Safety measures of BCVA, CDR, RNFL thickness and GC-IPL thickness remained stable through 8 years postoperative. VF-MD remained stable until postoperative year 5 and subsequently progressed according to the natural history of glaucomatous disease.ConclusionsImplantation of two iStents with concomitant cataract surgery is an effective and safe treatment option for surgery-naïve POAG eyes, evidenced by significant IOP and medication reductions, reasonable surgical success, and favorable safety outcomes, throughout the 8-year follow-up. Our data additionally supports the efficacy of this combined procedure in stabilizing or slowing disease progression.
Project description:IntroductionWe report 2-year outcomes after implantation of iStent trabecular micro-bypass stent with phacoemulsification, in Japanese patients with mild-moderate open-angle glaucoma (OAG).MethodsThis was a 24-month, prospective, longitudinal, observational, post-marketing study conducted between July 2017 and September 2020. Patients consisted of adults with OAG on antiglaucoma medications who had cataract surgery combined with one iStent implantation. Outcome measures included intraocular pressure (IOP), antiglaucoma medications, treatment success rates (defined as eyes having lower IOP with same or reduced number of medications from baseline, or same IOP with reduced number of medications from baseline, and not requiring secondary glaucoma surgeries postoperatively), and safety. Outcomes were analyzed in the overall cohort and in glaucoma subtypes: primary OAG, normal-tension glaucoma, and exfoliative glaucoma.ResultsOverall, 232 eyes were enrolled. At 24 months, mean ± standard deviation IOP decreased from 17.6 ± 4.0 mmHg preoperatively to 14.3 ± 3.0 mmHg (p < 0.05), and mean number of medications reduced from 2.2 ± 1.2 preoperatively to 0.7 ± 1.2 (p < 0.05). Similar trends were observed across glaucoma subtypes. In the overall cohort, 96.7%, 95.3%, and 93.7% of patients achieved treatment success at 6, 12, and 24 months, respectively. There were 67.6% medication-free eyes at 24 months compared to 3.2% medication-free eyes preoperatively (p < 0.0001). Safety profile was favorable over the 2-year period.ConclusionsFollowing iStent implantation with phacoemulsification, clinically relevant and statistically significant reductions in IOP and number of medications were observed in Japanese eyes with OAG over 2 years, with favorable safety profile. These reductions were observed across all glaucoma subtypes.
Project description:PurposeTo compare the outcomes of iStent vs. iStent inject implantation combined with phacoemulsification.MethodsThis single center retrospective comparative case series included subjects with open angle glaucoma who underwent iStent or iStent inject implantation combined with phacoemulsification with ≥1 year follow-up. The main outcome measures were in-group and between-group changes in intraocular pressure (IOP) and medication number, proportion of eyes that achieved IOP ≤15 mmHg, and surgical success defined as 20% IOP reduction from baseline at 6/12 months. Univariate/multivariate regression analyses were done to identify predictors of surgical failure.ResultsOne hundred ninety-seven eyes of 148 patients were included (122 iStent, 75 iStent inject). Both groups achieved significant IOP and medication reduction at months 6/12 (P < 0.05). At month 6, IOP was significantly lower in iStent inject vs. iStent eyes (P = 0.003), but the difference was insignificant by month 12 (P = 0.172). Medication number was comparable in both groups at months 6/12 (P > 0.05). More iStent inject eyes achieved IOP ≤15 mmHg at month 6 (P = 0.003) and 12 (P = 0.047). Surgical success was comparable in both groups at months 6/12 (P > 0.05). Kaplan-Meier survival analysis showed similar cumulative rate of surgical failure at year-1 in both groups (P = 0.644). The multivariate model identified older age (P = 0.017) and lower baseline IOP (P = 0.002) as the strongest predictors of surgical failure.ConclusionCompared to iStent, iStent inject achieved lower IOP at month 6 and higher proportion of eyes achieved IOP ≤15 mmHg at month 6/12. However, surgical success was similar in both groups. Predictors of surgical failure were older age and lower baseline IOP rather than the stent type.
Project description:PrcisThe iStent Infinite Trabecular Micro-Bypass System implanted in patients with open angle glaucoma (OAG) (uncontrolled by prior surgical or medical therapy) was effective in reducing mean diurnal intraocular pressure with a favorable safety profile.PurposeThe purpose of this study is to evaluate safety and effectiveness of the iStent infinite Trabecular Micro-Bypass System in patients with OAG uncontrolled by prior surgical or medical therapy.DesignProspective, multicenter, single-arm, open-label clinical trial.MethodsImplantation of iStent infinite (3 iStent inject W stents) was performed as a stand-alone surgical procedure in eyes with OAG uncontrolled by prior incisional or cilioablative surgeries or maximum tolerated medical therapy (MTMT). Prospectively declared effectiveness endpoints were proportion of eyes achieving ≥20% mean diurnal intraocular pressure (MDIOP) reduction from baseline at month 12 on the same or fewer intraocular pressure (IOP)-lowering medication classes (responder endpoint) and mean change in MDIOP from baseline at month 12. Safety parameters included visual acuity, slit-lamp and fundus examinations, gonioscopy, perimetry, surgical complications, and adverse events.ResultsSeventy-two eyes of 72 patients (mean age 71.9 y) with preoperative mean medicated MDIOP of 23.4±2.8 mm Hg on a mean of 3.1±0.9 IOP-lowering medication classes were enrolled: 61 eyes with failed prior surgery/ies (Failed-Surgery subgroup) and 11 eyes uncontrolled on MTMT (MTMT subgroup). A total of 76.1% of all enrolled patients met the responder endpoint (73.4% Failed-Surgery, 90.9% MTMT), with mean reduction (SE) in MDIOP at month 12 of 5.9(0.6) mm Hg [5.5(0.7) mm Hg Failed-Surgery subgroup, 8.1(0.9) mm Hg MTMT subgroup]. For patients on the same or fewer medication(s) as baseline, 53.0% achieved ≥30% MDIOP reduction without surgical interventions/other events. Safety was favorable, with no explants, infection, or device-related interventions or hypotony.ConclusionsiStent infinite stand-alone surgery achieved clinically significant IOP reduction and favorable safety in patients with OAG uncontrolled by prior therapy.
Project description:Recently introduced microincisional glaucoma surgeries that enhance conventional outflow offer a favorable risk profile over traditional surgeries, but can be unpredictable. Two paramount challenges are the lack of an adequate training model for angle surgeries and the absence of an intraoperative quantification of surgical success. To address both, we developed an ex vivo training system and a differential, quantitative canalography method that uses slope-adjusted fluorescence intensities of two different chromophores to avoid quenching. We assessed outflow enhancement by trabecular micro-bypass (TMB) implantation or by ab interno trabeculectomy (AIT). In this porcine model, TMB resulted in an insignificant (p > 0.05) outflow increase of 13 ± 5%, 14 ± 8%, 9 ± 3%, and 24 ± 9% in the inferonasal, superonasal, superotemporal, and inferotemporal quadrant, respectively. AIT caused a 100 ± 50% (p = 0.002), 75 ± 28% (p = 0.002), 19 ± 8%, and 40 ± 21% increase in those quadrants. The direct gonioscopy and tactile feedback provided a surgical experience that was very similar to that in human patients. Despite the more narrow and discontinuous circumferential drainage elements in the pig with potential for underperformance or partial stent obstruction, unequivocal patterns of focal outflow enhancement by TMB were seen in this training model. AIT achieved extensive access to outflow pathways beyond the surgical site itself.
Project description:PurposeThe study aimed to compare the 12-month post-operative outcomes of iStent and iStent inject W (inject W), and the factors associated with their success in open-angle glaucoma.MethodsThis single-center, retrospective comparative case series evaluated the medical records of patients who underwent iStent (comprising 1 stent) or inject W (comprising 2 stents) implantation with cataract surgery for primary open-angle glaucoma and normal tension glaucoma between January 2019 and March 2022. The 12-month post-operative efficacy outcomes included intraocular pressure (IOP), glaucoma medications, and survival analysis of the probability of success. "Failure" was defined as any of the following conditions compared to baseline: 1) IOP elevation, 2) increased glaucoma medication, or 3) IOP decline not exceeding 20% when glaucoma medication scores were comparable, and 4) need for additional glaucoma surgery. The safety outcomes included intra- and post-operative adverse events and changes in the best-corrected visual acuity and visual field.ResultsThe study comprised 55 eyes in the iStent and 105 in the inject W groups. At 12 months, treatment success was achieved in 66.0% of iStent and 78.4% of inject W eyes. The mean IOP was lower, and the percent reduction from baseline was equal in iStent-treated eyes (8.0% reduction, 14.8 mmHg to 13.7 mmHg, P<0.01) and inject W-treated eyes (11.9% reduction, 15.0 mmHg to 13.8 mmHg, P<0.01) (between-group comparison, P = 0.23). The mean medication burden decreased significantly from 2.5 to 1.1 for iStent (55.0% reduction, P<0.01) and 2.9 to 1.7 for iStent inject (46.8% reduction, P<0.01), with no significant differences between the two groups (P = 0.17). Both devices exhibited excellent safety.ConclusionsBoth devices significantly reduced IOP and glaucoma medication 12 months post-operatively. The outcome measures did not differ significantly between the two groups, and lower baseline IOP was predictive of surgical failure.
Project description:Background/objectivesTo describe intraocular pressure (IOP) and ocular hypotensive medication outcomes of combined phacoemulsification and ab interno trabeculectomy with the Kahook Dual Blade (KDB; New World Medical, Inc, Rancho Cucamonga, CA) in adults with cataract and open-angle glaucoma (OAG).Subjects/methodsRetrospective chart review of existing medical records. Data collected included intraocular pressure (IOP) and IOP-lowering medication use preoperatively and through up to 24 months postoperatively. Paired t-tests were utilized to compare preoperative to postoperative mean IOP and mean medications used.ResultsData from 32 eyes of 26 subjects were analyzed. Subjects were predominantly Caucasian (25/26) had mean (standard error) age of 79.3 (1.2) years, and eyes had moderate-advanced OAG (mean visual field mean deviation -8.3 [1.3] dB). Mean IOP was 19.8 (0.8) mmHg at baseline and 15.5 (0.6) mmHg (p<0.0001) after mean follow-up of 11.5 (1.0) months; IOP reductions of ≥20% were achieved in 20/32 eyes (62.5%). Mean medication use declined from 2.4 (0.2) medications per eye at baseline to 0.5 (0.2) at last follow-up (p<0.0001); 23/32 eyes (71.9%) were medication-free at last follow-up. No vision-threatening complications were observed.ConclusionsCombined phacoemulsification and ab interno trabeculectomy with the KDB safely provided mean IOP reductions of 21.7% and mean IOP medication reductions of 83% after mean follow-up of 12 months in eyes with moderate to advanced OAG. This procedure provides medication-independence in most eyes with statistically and clinically significant IOP reductions.