Unknown

Dataset Information

0

Development of electrochemical biosensor based on CNT-Fe3O4 nanocomposite to determine formaldehyde adulteration in orange juice.


ABSTRACT: An electrochemical biosensor was developed to determine formaldehyde (HCHO) adulteration commonly found in food. The current responses of various electrodes based on multiwalled carbon nanotubes (CNTs) and synthesized nanocomposite (CNT-Fe3O4) were measured using cyclic voltammetry. The nanocomposite based biosensor shows comparatively high sensitivity (527 µA mg/L-1 cm-2), low detection limit (0.05 mg/L) in linear detection range 0.05-0.5 mg/L for formaldehyde detection using formaldehyde dehydrogenase (FDH) enzyme. In real sample analysis, the low obtained RSD values (less than 1.79) and good recovery rates (more than 90%) signify an efficient and precise sensor for the selective quantification of formaldehyde in orange juice. The developed biosensor has future implications for determining formaldehyde adulteration in citrus fruit juices and other liquid foods in agri-food chain to further resolve global food safety concerns, control unethical business practices of adulteration and reduce the widespread food borne illness outbreaks.

SUBMITTER: Kundu M 

PROVIDER: S-EPMC6443716 | biostudies-literature | 2019 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Development of electrochemical biosensor based on CNT-Fe<sub>3</sub>O<sub>4</sub> nanocomposite to determine formaldehyde adulteration in orange juice.

Kundu Monika M   Bhardwaj Hema H   Pandey Manoj Kumar MK   Krishnan Prameela P   Kotnala R K RK   Sumana Gajjala G  

Journal of food science and technology 20190218 4


An electrochemical biosensor was developed to determine formaldehyde (HCHO) adulteration commonly found in food. The current responses of various electrodes based on multiwalled carbon nanotubes (CNTs) and synthesized nanocomposite (CNT-Fe<sub>3</sub>O<sub>4</sub>) were measured using cyclic voltammetry. The nanocomposite based biosensor shows comparatively high sensitivity (527 µA mg/L<sup>-1</sup> cm<sup>-2</sup>), low detection limit (0.05 mg/L) in linear detection range 0.05-0.5 mg/L for for  ...[more]

Similar Datasets

| S-EPMC9041725 | biostudies-literature
| S-EPMC6781078 | biostudies-literature
| S-EPMC6770506 | biostudies-literature
| S-EPMC6713753 | biostudies-literature
| S-EPMC9157531 | biostudies-literature
| S-EPMC6776962 | biostudies-literature
| S-EPMC6648138 | biostudies-literature
| S-EPMC9960270 | biostudies-literature
| S-EPMC6803758 | biostudies-literature
| S-EPMC9997073 | biostudies-literature