Unknown

Dataset Information

0

Real Time Microwave Biochemical Sensor Based on Circular SIW Approach for Aqueous Dielectric Detection.


ABSTRACT: In this study, a critical evaluation of analyte dielectric properties in a microvolume was undertaken, using a microwave biochemical sensor based on a circular substrate integrated waveguide (CSIW) topology. These dielectric properties were numerically investigated based on the resonant perturbation method, as this method provides the best sensing performance as a real-time biochemical detector. To validate these findings, shifts of the resonant frequency in the presence of aqueous solvents were compared with an ideal permittivity. The sensor prototype required a 2.5?µL volume of the liquid sample each time, which still offered an overall accuracy of better than 99.06%, with an average error measurement of ±0.44%, compared with the commercial and ideal permittivity values. The unloaded Qu factor of the circular substrate-integrated waveguide (CSIW) sensor achieved more than 400 to ensure a precise measurement. At 4.4?GHz, a good agreement was observed between simulated and measured results within a broad frequency range, from 1 to 6?GHz. The proposed sensor, therefore, offers high sensitivity detection, a simple structural design, a fast-sensing response, and cost-effectiveness. The proposed sensor in this study will facilitate real improvements in any material characterization applications such as pharmaceutical, bio-sensing, and food processing applications.

SUBMITTER: Mohd Bahar AA 

PROVIDER: S-EPMC6445140 | biostudies-literature | 2019 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Real Time Microwave Biochemical Sensor Based on Circular SIW Approach for Aqueous Dielectric Detection.

Mohd Bahar Amyrul Azuan AA   Zakaria Z Z   Md Arshad M K MK   Isa A A M AAM   Dasril Y Y   Alahnomi Rammah A RA  

Scientific reports 20190402 1


In this study, a critical evaluation of analyte dielectric properties in a microvolume was undertaken, using a microwave biochemical sensor based on a circular substrate integrated waveguide (CSIW) topology. These dielectric properties were numerically investigated based on the resonant perturbation method, as this method provides the best sensing performance as a real-time biochemical detector. To validate these findings, shifts of the resonant frequency in the presence of aqueous solvents were  ...[more]

Similar Datasets

| S-EPMC5764980 | biostudies-literature
| S-EPMC8069962 | biostudies-literature
| S-EPMC4440737 | biostudies-literature
| S-EPMC8429775 | biostudies-literature
| S-EPMC4725949 | biostudies-literature
| S-EPMC5691077 | biostudies-literature
| S-EPMC8292355 | biostudies-literature
| S-EPMC4655543 | biostudies-literature
| S-EPMC8626445 | biostudies-literature
| S-EPMC4802304 | biostudies-other