Unknown

Dataset Information

0

Three-Hour Delayed Imaging Improves Assessment of Coronary 18F-Sodium Fluoride PET.


ABSTRACT: Coronary 18F-sodium fluoride (18F-NaF) PET identifies ruptured plaques in patients with recent myocardial infarction and localizes to atherosclerotic lesions with active calcification. Most studies to date have performed the PET acquisition 1 h after injection. Although qualitative and semiquantitative analysis is feasible with 1-h images, residual blood-pool activity often makes it difficult to discriminate plaques with 18F-NaF uptake from noise. We aimed to assess whether delayed PET performed 3 h after injection improves image quality and uptake measurements. Methods: Twenty patients (67 ± 7 y old, 55% male) with stable coronary artery disease underwent coronary CT angiography (CTA) and PET/CT both 1 h and 3 h after the injection of 266.2 ± 13.3 MBq of 18F-NaF. We compared the visual pattern of coronary uptake, maximal background (blood pool) activity, noise, SUVmax, corrected SUVmax (cSUVmax), and target-to-background (TBR) ratio in lesions defined by CTA on 1-h versus 3-h 18F-NaF PET. Results: On 1-h PET, 26 CTA lesions with 18F-NaF PET uptake were identified in 12 (60%) patients. On 3-h PET, we detected 18F-NaF PET uptake in 7 lesions that were not identified on 1-h PET. The median cSUVmax and TBRs of these lesions were 0.48 (interquartile range [IQR], 0.44-0.51) and 1.45 (IQR, 1.39-1.52), respectively, compared with -0.01 (IQR, -0.03-0.001) and 0.95 (IQR, 0.90-0.98), respectively, on 1-h PET (both P < 0.001). Across the entire cohort, 3-h PET SUVmax was similar to 1-h PET measurements (1.63 [IQR, 1.37-1.98] vs. 1.55 [IQR, 1.43-1.89], P = 0.30), and the background activity was lower (0.71 [IQR, 0.65-0.81] vs. 1.24 [IQR, 1.05-1.31], P < 0.001). On 3-h PET, TBR, cSUVmax, and noise were significantly higher (respectively: 2.30 [IQR, 1.70-2.68] vs. 1.28 [IQR, 0.98-1.56], P < 0.001; 0.38 [IQR, 0.27-0.70] vs. 0.90 [IQR, 0.64-1.17], P < 0.001; and 0.10 [IQR, 0.09-0.12] vs. 0.07 [IQR, 0.06-0.09], P = 0.02). Median cSUVmax and TBR increased by 92% (range, 33%-225%) and 80% (range, 20%-177%), respectively. Conclusion: Blood-pool activity decreases on delayed imaging, facilitating the assessment of 18F-NaF uptake in coronary plaques. Median TBR increases by 80%, leading to the detection of more plaques with significant uptake than are detected using the standard 1-h protocol. A greater than 1-h delay may improve the detection of 18F-NaF uptake in coronary artery plaques.

SUBMITTER: Kwiecinski J 

PROVIDER: S-EPMC6448466 | biostudies-literature | 2019 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Three-Hour Delayed Imaging Improves Assessment of Coronary <sup>18</sup>F-Sodium Fluoride PET.

Kwiecinski Jacek J   Berman Daniel S DS   Lee Sang-Eun SE   Dey Damini D   Cadet Sebastien S   Lassen Martin L ML   Germano Guido G   Jansen Maurits A MA   Dweck Marc R MR   Newby David E DE   Chang Hyuk-Jae HJ   Yun Mijin M   Slomka Piotr J PJ  

Journal of nuclear medicine : official publication, Society of Nuclear Medicine 20180913 4


Coronary <sup>18</sup>F-sodium fluoride (<sup>18</sup>F-NaF) PET identifies ruptured plaques in patients with recent myocardial infarction and localizes to atherosclerotic lesions with active calcification. Most studies to date have performed the PET acquisition 1 h after injection. Although qualitative and semiquantitative analysis is feasible with 1-h images, residual blood-pool activity often makes it difficult to discriminate plaques with <sup>18</sup>F-NaF uptake from noise. We aimed to ass  ...[more]

Similar Datasets

| S-EPMC7271818 | biostudies-literature
| S-EPMC7953548 | biostudies-literature
| S-EPMC7380446 | biostudies-literature
| S-EPMC7246165 | biostudies-literature
| S-EPMC7911917 | biostudies-literature
| S-EPMC7775905 | biostudies-literature
| S-EPMC6899769 | biostudies-literature
| S-EPMC6267920 | biostudies-literature
| S-EPMC7771641 | biostudies-literature
| S-EPMC8789749 | biostudies-literature