Unknown

Dataset Information

0

Magnetic Cytoskeleton Affinity Purification of Microtubule Motors Conjugated to Quantum Dots.


ABSTRACT: We develop magnetic cytoskeleton affinity (MiCA) purification, which allows for rapid isolation of molecular motors conjugated to large multivalent quantum dots, in miniscule quantities, which is especially useful for single-molecule applications. When purifying labeled molecular motors, an excess of fluorophores or labels is usually used. However, large labels tend to sediment during the centrifugation step of microtubule affinity purification, a traditionally powerful technique for motor purification. This is solved with MiCA, and purification time is cut from 2 h to 20 min, a significant time-savings when it needs to be done daily. For kinesin, MiCA works with as little as 0.6 ?g protein, with yield of ?27%, compared to 41% with traditional purification. We show the utility of MiCA purification in a force-gliding assay with kinesin, allowing, for the first time, simultaneous determination of whether the force from each motor in a multiple-motor system drives or hinders microtubule movement. Furthermore, we demonstrate rapid purification of just 30 ng dynein-dynactin-BICD2N-QD (DDB-QD), ordinarily a difficult protein-complex to purify.

SUBMITTER: Tjioe M 

PROVIDER: S-EPMC6452869 | biostudies-literature | 2018 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Magnetic Cytoskeleton Affinity Purification of Microtubule Motors Conjugated to Quantum Dots.

Tjioe Marco M   Ryoo Hyeon H   Ishitsuka Yuji Y   Ge Pinghua P   Bookwalter Carol C   Huynh Walter W   McKenney Richard J RJ   Trybus Kathleen M KM   Selvin Paul R PR  

Bioconjugate chemistry 20180703 7


We develop magnetic cytoskeleton affinity (MiCA) purification, which allows for rapid isolation of molecular motors conjugated to large multivalent quantum dots, in miniscule quantities, which is especially useful for single-molecule applications. When purifying labeled molecular motors, an excess of fluorophores or labels is usually used. However, large labels tend to sediment during the centrifugation step of microtubule affinity purification, a traditionally powerful technique for motor purif  ...[more]

Similar Datasets

| S-EPMC8243741 | biostudies-literature
| S-EPMC9230973 | biostudies-literature
| S-EPMC2553244 | biostudies-literature
| S-EPMC3231291 | biostudies-literature
2021-01-30 | GSE165805 | GEO
| S-EPMC2919412 | biostudies-literature
| S-EPMC5221621 | biostudies-literature
| S-EPMC3947824 | biostudies-literature
| S-EPMC8470909 | biostudies-literature
| S-EPMC3788368 | biostudies-literature