A Novel Wearable Device for Continuous Ambulatory ECG Recording: Proof of Concept and Assessment of Signal Quality.


ABSTRACT: Diagnosis of arrhythmic disorders is challenging because of their short-lasting, intermittent character. Conventional technologies of noninvasive ambulatory rhythm monitoring are limited by modest sensitivity. We present a novel form of wearable electrocardiogram (ECG) sensors providing an alternative tool for long-term rhythm monitoring with the potential of increased sensitivity to detect intermittent or subclinical arrhythmia. The objective was to assess the signal quality and R-R coverage of a wearable ECG sensor system compared to a standard 3-lead Holter. In this phase-1 trial, healthy individuals underwent 24-h simultaneous rhythm monitoring using the OMsignal system together with a 3-lead Holter recording. The OMsignal system consists of a garment (bra or shirt) with integrated sensors recording a single-lead ECG and an acquisition module for data storage and processing. Head-to-head signal quality was assessed regarding adequate P-QRS-T distinction and was performed by three electrophysiologists blinded to the recording technology. The accuracy of signal coverage was assessed using Bland-Altman analysis. Fifteen individuals underwent simultaneous 24-h recording. Signal quality and accuracy of the OMgaments was equivalent to Holter-monitoring (84% vs 93% electrophysiologists rating, p = 0.06). Signal coverage of R-R intervals showed a very close overlay between the OMsignal system and Holter signals, mean difference in heart rate of 2 5 bpm. The noise level of OMgarments was comparable to Holter recording. OMgarments provide high signal quality for adequate rhythm analysis, representing a promising novel technology for long-term non-invasive ECG monitoring.

SUBMITTER: Steinberg C 

PROVIDER: S-EPMC6468449 | biostudies-literature | 2019 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

A Novel Wearable Device for Continuous Ambulatory ECG Recording: Proof of Concept and Assessment of Signal Quality.

Steinberg Christian C   Philippon François F   Sanchez Marina M   Fortier-Poisson Pascal P   O'Hara Gilles G   Molin Franck F   Sarrazin Jean-François JF   Nault Isabelle I   Blier Louis L   Roy Karine K   Plourde Benoit B   Champagne Jean J  

Biosensors 20190121 1


Diagnosis of arrhythmic disorders is challenging because of their short-lasting, intermittent character. Conventional technologies of noninvasive ambulatory rhythm monitoring are limited by modest sensitivity. We present a novel form of wearable electrocardiogram (ECG) sensors providing an alternative tool for long-term rhythm monitoring with the potential of increased sensitivity to detect intermittent or subclinical arrhythmia. The objective was to assess the signal quality and R-R coverage of  ...[more]

Similar Datasets

| S-EPMC7669461 | biostudies-literature
| S-EPMC7499164 | biostudies-literature
| S-EPMC7925259 | biostudies-literature
| S-EPMC5030218 | biostudies-literature
| S-EPMC9320854 | biostudies-literature
| S-EPMC8289189 | biostudies-literature
| S-EPMC7273241 | biostudies-literature
| S-EPMC7690815 | biostudies-literature
| S-EPMC6682266 | biostudies-literature
| S-EPMC8460982 | biostudies-literature