Unknown

Dataset Information

0

Determination of Urinary Pterins by Capillary Electrophoresis Coupled with LED-Induced Fluorescence Detector.


ABSTRACT: Urinary pterins have been found as potential biomarkers in many pathophysiological conditions including inflammation, viral infections, and cancer. However, pterins determination in biological samples is difficult due to their degradation under exposure to air, light, and heat. Besides, they occur at shallow concentration levels, and thus, standard UV detectors cannot be used without additional sample preconcentration. On the other hand, ultra-sensitive laser-induced fluorescence (LIF) detection can be used since pterins exhibit native fluorescence. The main factor that limits an everyday use of LIF detectors is its high price. Here, an alternative detector, i.e., light-emitted diode induced fluorescence (LEDIF) detector, was evaluated for the determination of pterins in urine samples after capillary electrophoresis (CE) separation. An optimized method was validated in terms of linearity range, limit of detection (LOD), limit of quantification (LOQ), intra- and interday precision and accuracy, sample stability in the autosampler, and sample stability during the freezing/thawing cycle. The obtained LOD (0.1 µM) and LOQ (0.3 µM) values were three-order of magnitude lower compared to UV detector, and two orders of magnitude higher compared to previously reported house-built LIF detector. The applicability of the validated method was demonstrated in the analysis of urine samples from healthy individuals and cancer patients.

SUBMITTER: Grochocki W 

PROVIDER: S-EPMC6470587 | biostudies-literature | 2019 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Determination of Urinary Pterins by Capillary Electrophoresis Coupled with LED-Induced Fluorescence Detector.

Grochocki Wojciech W   Buszewska-Forajta Magdalena M   Macioszek Szymon S   Markuszewski Michał J MJ  

Molecules (Basel, Switzerland) 20190324 6


Urinary pterins have been found as potential biomarkers in many pathophysiological conditions including inflammation, viral infections, and cancer. However, pterins determination in biological samples is difficult due to their degradation under exposure to air, light, and heat. Besides, they occur at shallow concentration levels, and thus, standard UV detectors cannot be used without additional sample preconcentration. On the other hand, ultra-sensitive laser-induced fluorescence (LIF) detection  ...[more]

Similar Datasets

| S-EPMC6100306 | biostudies-literature
| S-EPMC4966509 | biostudies-literature
| S-EPMC4215805 | biostudies-literature
| S-EPMC3409464 | biostudies-literature
| S-EPMC5789010 | biostudies-literature
| S-EPMC5046087 | biostudies-other
| S-EPMC2764549 | biostudies-literature
| S-EPMC3031587 | biostudies-literature
| S-EPMC3872064 | biostudies-literature
| S-EPMC3164759 | biostudies-literature