Unknown

Dataset Information

0

Development and evaluation of a multiplex reverse-transcription real-time PCR assay for detection of equine respiratory disease viruses.


ABSTRACT: We developed a multiplex reverse-transcription real-time PCR (RT-rtPCR) assay for the simultaneous detection of the main equine respiratory viruses: equid alphaherpesviruses 1 and 4 (EHV-1, -4) and equine influenza virus (EIV; species Influenza A virus). The primers and probes amplified only the targeted viruses, and there were no inter-assay cross-amplifications or nonspecific interactions. The multiplex assay efficiencies were 92.5%, 97%, and 90% for EHV-1, EHV-4, and EIV, respectively. The R2 values of the monoplex and multiplex assays were ⩾0.990, and the slopes were -3.37 to -3.59. The performance of the assay was evaluated by analyzing 152 samples from clinically infected horses. EHV-1 DNA was detected in 12 samples, EHV-4 DNA in 9 samples, and both EHV-1 and EHV-4 in 4 samples. The accuracy of the assay was confirmed by comparing these results using commercial rtPCR and RT-rtPCR kits. Our multiplex RT-rtPCR was a sensitive, specific, accurate, and cost-effective method for the detection of the target viruses whether they occur alone or as part of coinfections.

SUBMITTER: Ghoniem SM 

PROVIDER: S-EPMC6505849 | biostudies-literature | 2018 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Development and evaluation of a multiplex reverse-transcription real-time PCR assay for detection of equine respiratory disease viruses.

Ghoniem Shimaa M SM   El Deeb Ayman H AH   Aggour Mohammed G MG   Hussein Hussein A HA  

Journal of veterinary diagnostic investigation : official publication of the American Association of Veterinary Laboratory Diagnosticians, Inc 20180921 6


We developed a multiplex reverse-transcription real-time PCR (RT-rtPCR) assay for the simultaneous detection of the main equine respiratory viruses: equid alphaherpesviruses 1 and 4 (EHV-1, -4) and equine influenza virus (EIV; species Influenza A virus). The primers and probes amplified only the targeted viruses, and there were no inter-assay cross-amplifications or nonspecific interactions. The multiplex assay efficiencies were 92.5%, 97%, and 90% for EHV-1, EHV-4, and EIV, respectively. The R<  ...[more]

Similar Datasets

| S-EPMC6440764 | biostudies-literature
| S-EPMC3911421 | biostudies-literature
| S-EPMC3542198 | biostudies-literature
| S-EPMC10796610 | biostudies-literature
| S-EPMC4646456 | biostudies-other
| S-EPMC4400749 | biostudies-literature
| S-EPMC153860 | biostudies-literature
| S-EPMC7091384 | biostudies-literature
| S-EPMC2238069 | biostudies-literature