Unknown

Dataset Information

0

Using the pCANvas neck-bridging device in treating a wide-necked aneurysm of the basilar tip.


ABSTRACT:

Background and importance

The endovascular treatment of recurrent wide-necked bifurcation aneurysms at the basilar tip remains very challenging. Many different techniques and devices have emerged in recent years as potential options but results remain less than controversial. The pCANvas is a relatively new device wielding neck-bridging properties with a haemodynamically active membrane acting as blood flow disrupter.

Clinical presentation

We present the clinical case of a patient in whom multiple endovascular and microsurgical attempts failed to achieve the definitive treatment of a large and wide-necked basilar tip aneurysm. The patient underwent successful endovascular implantation of the novel pCANvas device across the recurrent aneurysm neck. The device limited the blood flow to the anerysmal lumen and thus promoted faster thrombosis. Third month follow-up confirmed complete obliteration of the aneurysm.

Conclusion

The application of the pCANvas device offers a potential treatment option in difficult and recurrent aneurysms. The endovascular flow disruption is a relatively new feature aiming to create conditions for intraluminal thrombosis and is certainly promising for the treatment of complex bifurcation aneurysms.

SUBMITTER: Sirakov S 

PROVIDER: S-EPMC6512211 | biostudies-literature | 2019 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Using the pCANvas neck-bridging device in treating a wide-necked aneurysm of the basilar tip.

Sirakov Stanimir S   Panayotova Adriana A   Sirakov Alexander A   Penkov Marin M   Minkin Krasimir K   Hristov Hristo H  

The neuroradiology journal 20190403 3


<h4>Background and importance</h4>The endovascular treatment of recurrent wide-necked bifurcation aneurysms at the basilar tip remains very challenging. Many different techniques and devices have emerged in recent years as potential options but results remain less than controversial. The pCANvas is a relatively new device wielding neck-bridging properties with a haemodynamically active membrane acting as blood flow disrupter.<h4>Clinical presentation</h4>We present the clinical case of a patient  ...[more]

Similar Datasets

| S-EPMC4513504 | biostudies-other
| S-EPMC8315690 | biostudies-literature
| S-EPMC5309464 | biostudies-literature
| S-EPMC8762371 | biostudies-literature
| S-EPMC7903548 | biostudies-literature
| S-EPMC4212997 | biostudies-literature
| S-EPMC6435532 | biostudies-literature
| S-EPMC8829485 | biostudies-literature
| S-EPMC6896639 | biostudies-literature
| S-EPMC5800678 | biostudies-literature