Unknown

Dataset Information

0

Hemodynamic impacts of flow diverter devices on the ophthalmic artery.


ABSTRACT:

Background

Flow diverter devices are increasingly used for endovascular treatment of internal carotid artery aneurysms. Treatment of ophthalmic segment aneurysms with flow diverter devices also includes coverage of the ophthalmic artery but may result in complications. It is unclear, however, whether these devices mechanically block blood flow in the ophthalmic artery. Also unclear is the relationship between deployment of a flow diverter device and post-treatment occlusion. We studied hemodynamic changes in the ophthalmic artery after deployment of a flow diverter device to determine the relationship between those changes and post-stent occlusion of the artery.

Methods

We analyzed hemodynamic modifications in the ophthalmic artery in 21 patients (19 women, 2 men; mean age 53.43?±?7.32 years) treated by a single pipeline embolization device. Patient-specific geometries were determined from three-dimensional digital subtraction angiography and the stenting process was simulated. Computational fluid dynamics technology was used to analyze the change in ophthalmic artery hemodynamics. We compared pre-treatment and post-treatment flow velocity of the ophthalmic artery.

Results

Among the 21 patients with aneurysms located in the ophthalmic segment, no ophthalmic artery occlusion was found during immediate or follow-up angiography. Post-stent flow velocity in the ophthalmic artery decreased from 0.35?±?0.19 to 0.33?±?0.20 m/s, with the difference not being statistically significant (P?=?0.106).

Conclusion

Our results showed no significant change in ophthalmic artery blood flow after pipeline embolization device deployment. Hence, post-stent occlusion of the ophthalmic artery could not be explained by reduced blood flow. Delayed thrombosis and neointimal formation maybe the keys to ophthalmic artery occlusion and need further investigation.

SUBMITTER: Wu X 

PROVIDER: S-EPMC6524319 | biostudies-literature | 2019 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Hemodynamic impacts of flow diverter devices on the ophthalmic artery.

Wu Xinzhi X   Tian Zhongbin Z   Liu Jian J   Li Wenqiang W   Chen Junfan J   Zhou Yangyang Y   Yang Xinjian X   Mu Shiqing S  

Journal of translational medicine 20190516 1


<h4>Background</h4>Flow diverter devices are increasingly used for endovascular treatment of internal carotid artery aneurysms. Treatment of ophthalmic segment aneurysms with flow diverter devices also includes coverage of the ophthalmic artery but may result in complications. It is unclear, however, whether these devices mechanically block blood flow in the ophthalmic artery. Also unclear is the relationship between deployment of a flow diverter device and post-treatment occlusion. We studied h  ...[more]

Similar Datasets

| S-EPMC2892638 | biostudies-literature
| S-EPMC4781985 | biostudies-literature
| S-EPMC4806313 | biostudies-literature
| S-EPMC7585392 | biostudies-literature
| S-EPMC7593745 | biostudies-literature
| S-EPMC5352494 | biostudies-literature
| S-EPMC6838848 | biostudies-literature
| S-EPMC5473091 | biostudies-other
| S-EPMC7591168 | biostudies-literature
| S-EPMC7968752 | biostudies-literature