Unknown

Dataset Information

0

Repeatability of choroidal thickness measurements with Spectralis OCT images.


ABSTRACT: Objective:To investigate the repeatability of choroidal thickness measurements determined from enhanced depth imaging optical coherence tomography (EDI-OCT) images of eyes after wearing single-vision spectacles (SV) and orthokeratology (ortho-k) lenses. Methods and analysis:Two EDI-OCT images of 40 children (SV: 20, ortho-k: 20) taken at a single visit were analysed twice. Subjects in the ortho-k group had been wearing ortho-k for 1-4 weeks. The choroidal thickness was determined from each image using a graph theory-based software and, where appropriate, manual correction of choroidal boundaries was undertaken by an experienced examiner. Results:The mean (±SD) choroidal thickness was 227.3±42.2?µm for the SV subjects and 251.1±54.4?µm for the ortho-k subjects. The interimage differences in choroidal thickness were -0.99±3.54?and -1.14±5.03?µm for the SV and ortho-k subjects, respectively, and the limits of agreement were +5.96?to -7.93 and +8.72?to -11.00 µm, respectively. Conclusion:The coefficients of repeatability of choroidal thickness measurements from two EDI-OCT images taken at a single visit were 7.08?µm (SV) and 10.06?µm (ortho-k), suggesting that a change in choroidal thickness of less than 10 µm may not indicate a real change resulting from ortho-k lens wear.

SUBMITTER: Lau JK 

PROVIDER: S-EPMC6528750 | biostudies-literature | 2019

REPOSITORIES: biostudies-literature

altmetric image

Publications

Repeatability of choroidal thickness measurements with Spectralis OCT images.

Lau Jason K JK   Cheung Sin Wan SW   Collins Michael J MJ   Cho Pauline P  

BMJ open ophthalmology 20190423 1


<h4>Objective</h4>To investigate the repeatability of choroidal thickness measurements determined from enhanced depth imaging optical coherence tomography (EDI-OCT) images of eyes after wearing single-vision spectacles (SV) and orthokeratology (ortho-k) lenses.<h4>Methods and analysis</h4>Two EDI-OCT images of 40 children (SV: 20, ortho-k: 20) taken at a single visit were analysed twice. Subjects in the ortho-k group had been wearing ortho-k for 1-4 weeks. The choroidal thickness was determined  ...[more]

Similar Datasets

| S-EPMC5687829 | biostudies-literature
| S-EPMC5755895 | biostudies-literature
| S-EPMC6062033 | biostudies-literature
| S-EPMC6746702 | biostudies-literature
| S-EPMC7401852 | biostudies-literature
| S-EPMC4482384 | biostudies-literature
| S-EPMC8727314 | biostudies-literature
| S-EPMC5361145 | biostudies-literature
| S-EPMC5596889 | biostudies-literature
| S-EPMC6543924 | biostudies-literature