Unknown

Dataset Information

0

Safety of in-hospital insertable cardiac monitor procedures performed outside the traditional settings: results from the Reveal LINQ in-office 2 international study.


ABSTRACT: BACKGROUND:Historically, the majority of insertable cardiac monitor (ICM) procedures were performed in the cardiac catheterization (cath) lab, electrophysiology (EP) lab, or operating room (OR). The miniaturization of ICMs allows the procedure to be relocated within the hospital without compromising patient safety. We sought to estimate the rate of untoward events associated with procedures performed within the hospital but outside the traditional settings and to characterize resource utilization, procedure time intervals, and physician experience. METHODS:The Reveal LINQ in-Office 2 (RIO 2) International study was a single arm, multicenter, prospective study. Patients indicated for an ICM and willing to undergo device insertion outside the cath/EP lab or OR were eligible and followed for 90?days after insertion. RESULTS:A total of 191 patients (45.5% female aged 63.8?±?26.9?years) underwent successful Reveal LINQ ICM insertion at 17 centers in Europe, Canada and Australia. The median total visit duration was 106?min (interquartile range [IQR]: 55-61). Patient preparation and patient education accounted for 10?min (IQR: 5-20) and 10?min (IQR: 8-15) of total visit duration, respectively. Preparation and education occurred in the procedure room for 90.6 and 60.2% of patients, respectively. There were no untoward events (0.0, 95% CI: 0.0-2.1%) though four patients presented with procedure-related adverse events that did not require invasive intervention. Physicians rated procedure location as convenient or very convenient. CONCLUSIONS:The Reveal LINQ™ ICM insertion can be safely and efficiently performed in the hospital outside the cath/EP lab or OR. TRIAL REGISTRATION:ClinicalTrials.gov identifier NCT02412488 ; registered on April 9, 2015.

SUBMITTER: Sanders P 

PROVIDER: S-EPMC6545016 | biostudies-literature | 2019 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Safety of in-hospital insertable cardiac monitor procedures performed outside the traditional settings: results from the Reveal LINQ in-office 2 international study.

Sanders Prashanthan P   Piorkowski Christopher C   Kragten Johannes A JA   Goode Grahame K GK   Raj Satish R SR   Dinh Trang T   Sohail M Rizwan MR   Anand Rishi R   Moya-Mitjans Angel A   Franco Noreli N   Stromberg Kurt K   Rogers John D JD  

BMC cardiovascular disorders 20190531 1


<h4>Background</h4>Historically, the majority of insertable cardiac monitor (ICM) procedures were performed in the cardiac catheterization (cath) lab, electrophysiology (EP) lab, or operating room (OR). The miniaturization of ICMs allows the procedure to be relocated within the hospital without compromising patient safety. We sought to estimate the rate of untoward events associated with procedures performed within the hospital but outside the traditional settings and to characterize resource ut  ...[more]

Similar Datasets

| S-EPMC3744555 | biostudies-literature
| S-EPMC8029679 | biostudies-literature
| S-EPMC5673395 | biostudies-literature
| S-EPMC7496021 | biostudies-literature
| S-EPMC6593196 | biostudies-literature
| S-EPMC9043368 | biostudies-literature
| S-EPMC7483782 | biostudies-literature
| S-EPMC5948536 | biostudies-literature
| S-EPMC6702360 | biostudies-literature
| S-EPMC6811667 | biostudies-other