Lag Time Remains with Newer Real-Time Continuous Glucose Monitoring Technology During Aerobic Exercise in Adults Living with Type 1 Diabetes.


ABSTRACT: Background: Real-time continuous glucose monitoring (CGM) devices help detect glycemic excursions associated with exercise, meals, and insulin dosing in patients with type 1 diabetes (T1D). However, the delay between interstitial and blood glucose may result in CGM underestimating the true change in glycemia during activity. The purpose of this study was to examine CGM discrepancies during exercise and the meal postexercise versus self-monitoring of blood glucose (SMBG). Methods: Seventeen adults with T1D using insulin pump therapy and CGM completed 60?min of aerobic exercise on three occasions. A standardized meal was given 30?min postexercise. SMBG was measured during exercise and in recovery using OmniPod® Personal Diabetes Manager (PDM; Insulet, Billerica, MA) with built-in glucose meter (FreeStyle; Abbott Laboratories, Abbott Park, IL), while CGM was measured with Dexcom G4® with 505 algorithm (n?=?4) or G5® (n?=?13), which were calibrated with subjects' own PDM. Results: SMBG showed a large drop in glycemia during exercise, while CGM showed a lag of 12?±?11 (mean?±?standard deviation) minutes and bias of -7?±?19 mg/dL/min during activity. Mean absolute relative difference (MARD) for CGM versus SMBG was 13 (6-22)% [median (interquartile range)] during exercise and 8 (5-14)% during mealtime. Clarke error grids showed CGM values were in zones A and B 94%-99% of the time for SMBG. Conclusion: In summary, the drop in CGM lags behind the drop in blood glucose during prolonged aerobic exercise by 12?±?11?min, and MARD increases to 13 (6-22)% during exercise as well. Therefore, if hypoglycemia is suspected during exercise, individuals should confirm glucose levels with a capillary glucose measurement.

SUBMITTER: Zaharieva DP 

PROVIDER: S-EPMC6551983 | biostudies-literature | 2019 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Lag Time Remains with Newer Real-Time Continuous Glucose Monitoring Technology During Aerobic Exercise in Adults Living with Type 1 Diabetes.

Zaharieva Dessi P DP   Turksoy Kamuran K   McGaugh Sarah M SM   Pooni Rubin R   Vienneau Todd T   Ly Trang T   Riddell Michael C MC  

Diabetes technology & therapeutics 20190506 6


<b><i>Background:</i></b> Real-time continuous glucose monitoring (CGM) devices help detect glycemic excursions associated with exercise, meals, and insulin dosing in patients with type 1 diabetes (T1D). However, the delay between interstitial and blood glucose may result in CGM underestimating the true change in glycemia during activity. The purpose of this study was to examine CGM discrepancies during exercise and the meal postexercise versus self-monitoring of blood glucose (SMBG). <b><i>Meth  ...[more]

Similar Datasets

| S-EPMC5602456 | biostudies-other
| S-EPMC10986633 | biostudies-literature
| S-EPMC3849820 | biostudies-literature
| S-EPMC7736459 | biostudies-literature
| S-EPMC8706065 | biostudies-literature
| S-EPMC9202557 | biostudies-literature
| S-EPMC6023779 | biostudies-literature
| S-EPMC7748959 | biostudies-literature
| S-EPMC6312392 | biostudies-literature
| S-EPMC3462246 | biostudies-literature