Unknown

Dataset Information

0

Comparison of treatment planning approaches for spatially fractionated irradiation of deep tumors.


ABSTRACT: PURPOSE:The purpose of this work was to compare the dosimetry and delivery times of 3D-conformal (3DCRT)-, volumetric modulated arc therapy (VMAT)-, and tomotherapy-based approaches for spatially fractionated radiation therapy for deep tumor targets. METHODS:Two virtual GRID phantoms were created consisting of 7 "target" cylinders (1-cm diameter) aligned longitudinally along the tumor in a honey-comb pattern, mimicking a conventional GRID block, with 2-cm center-to-center spacing (GRID2 cm ) and 3-cm center-to-center spacing (GRID3 cm ), all contained within a larger cylinder (8 and 10 cm in diameter for the GRID2 cm and GRID3 cm , respectively). In a single patient, a GRID3 cm structure was created within the gross tumor volume (GTV). Tomotherapy, VMAT (6 MV + 6 MV-flattening-filter-free) and multi-leaf collimator segment 3DCRT (6 MV) plans were created using commercially available software. Two tomotherapy plans were created with field widths (TOMO2.5 cm ) 2.5 cm and (TOMO5 cm ) 5 cm. Prescriptions for all plans were set to deliver a mean dose of 15 Gy to the GRID targets in one fraction. The mean dose to the GRID target and the heterogeneity of the dose distribution (peak-to-valley and peak-to-edge dose ratios) inside the GRID target were obtained. The volume of normal tissue receiving 7.5 Gy was determined. RESULTS:The peak-to-valley ratios for GRID2 cm /GRID3 cm /Patient were 2.1/2.3/2.8, 1.7/1.5/2.8, 1.7/1.9/2.4, and 1.8/2.0/2.8 for the 3DCRT, VMAT, TOMO5 cm , and TOMO2.5 cm plans, respectively. The peak-to-edge ratios for GRID2 cm /GRID3 cm /Patient were 2.8/3.2/5.4, 2.1/1.8/5.4, 2.0/2.2/3.9, 2.1/2.7/5.2 and for the 3DCRT, VMAT, TOMO5 cm , and TOMO2.5 cm plans, respectively. The volume of normal tissue receiving 7.5 Gy was lowest in the TOMO2.5 cm plan (GRID2 cm /GRID3 cm /Patient = 54 cm3 /19 cm3 /10 cm3 ). The VMAT plans had the lowest delivery times (GRID2 cm /GRID3 cm /Patient = 17 min/8 min/9 min). CONCLUSION:Our results present, for the first time, preliminary evidence comparing IMRT-GRID approaches which result in high-dose "islands" within a target, mimicking what is achieved with a conventional GRID block but without high-dose "tail" regions outside of the target. These approaches differ modestly in their ability to achieve high peak-to-edge ratios and also differ in delivery times.

SUBMITTER: Sheikh K 

PROVIDER: S-EPMC6560243 | biostudies-literature | 2019 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparison of treatment planning approaches for spatially fractionated irradiation of deep tumors.

Sheikh Khadija K   Hrinivich William T WT   Bell Leslie A LA   Moore Joseph A JA   Laub Wolfram W   Viswanathan Akila N AN   Yan Yulong Y   McNutt Todd R TR   Meyer Jeffrey J  

Journal of applied clinical medical physics 20190521 6


<h4>Purpose</h4>The purpose of this work was to compare the dosimetry and delivery times of 3D-conformal (3DCRT)-, volumetric modulated arc therapy (VMAT)-, and tomotherapy-based approaches for spatially fractionated radiation therapy for deep tumor targets.<h4>Methods</h4>Two virtual GRID phantoms were created consisting of 7 "target" cylinders (1-cm diameter) aligned longitudinally along the tumor in a honey-comb pattern, mimicking a conventional GRID block, with 2-cm center-to-center spacing  ...[more]

Similar Datasets

| S-EPMC8233471 | biostudies-literature
| S-EPMC2843684 | biostudies-literature
| S-EPMC3732275 | biostudies-literature
| S-EPMC8295841 | biostudies-literature
| S-EPMC6249773 | biostudies-literature
| S-EPMC4670078 | biostudies-literature
| S-EPMC3281012 | biostudies-literature
2018-07-01 | GSE56113 | GEO
| S-EPMC3594421 | biostudies-literature
| S-EPMC7246074 | biostudies-literature